Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate

Radiology. 2012 Jan;262(1):314-9. doi: 10.1148/radiol.11103506. Epub 2011 Nov 21.

Abstract

Purpose: To assess the effect of a rapid needle-out patient-rollover time approach on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary nodules.

Materials and methods: The institutional review board approved the study, and all patients gave written informed consent. Between January 2008 and December 2009, percutaneous CT-guided lung biopsy was performed in 201 patients. Eighty-one biopsies were performed without (group 1) and 120 were performed with (group 2) a rapid needle-out patient-rollover time approach (defined as the time between removal of the biopsy needle and placing the patient biopsy-side down). Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographic characteristics, lesion characteristics, and biopsy technique.

Results: Mean rapid needle-out patient-rollover time (± standard deviation) was 9.5 seconds ± 4.8. Seventy-six percent of patients (75 of 98) achieved a needle-out patient-rollover time of 10 seconds or less. Unsuitability for the rapid needle-out patient-rollover time technique resulted in exclusion of 1.8% of patients. An increased number of pneumothoraces (25 [37%] vs 22 [23%]; P = .04) and an increased number of drainage catheter insertions were noted in group 1 compared with group 2 (10 [15%] versus four [4%], respectively; P = .029). At multiple regression analysis for group 1, lesion size and emphysema along the needle track were independent risk factors for pneumothorax (P = .032 and .021, respectively), and emphysema along the needle track was an independent predictor for insertion of a drainage catheter (P = .005). No independent predictor was identified for pneumothorax or insertion of a drainage catheter in group 2.

Conclusion: Rapid needle-out patient-rollover time during percutaneous CT-guided transthoracic lung biopsy reduces the rate of overall pneumothorax and pneumothorax necessitating a drainage catheter. Use of this technique attenuates the influence of traditional risk factors for pneumothorax.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Needle / methods*
  • Chi-Square Distribution
  • Female
  • Humans
  • Logistic Models
  • Lung Neoplasms / diagnostic imaging
  • Lung Neoplasms / pathology*
  • Male
  • Middle Aged
  • Patient Positioning
  • Pneumothorax / epidemiology*
  • Radiography, Interventional / methods*
  • Radiography, Thoracic / methods*
  • Risk Factors
  • Time Factors
  • Tomography, X-Ray Computed / methods*