Patient-prosthesis mismatch after transapical aortic valve implantation: incidence and impact on survival

J Thorac Cardiovasc Surg. 2013 Feb;145(2):391-7. doi: 10.1016/j.jtcvs.2012.01.043. Epub 2012 Feb 11.

Abstract

Objectives: Transcatheter aortic valve implantation (TAVI) has become an important therapeutic option for high-risk patients with severe aortic valve stenosis. Patient-prosthesis mismatch (P-PM) is an important determinant of morbidity and mortality after open aortic valve replacement. The objective of our study was to evaluate P-PM incidence and its impact on survival in a large cohort of patients treated with TAVI.

Methods and results: We retrospectively analyzed transesophageal echocardiographic data of 278 consecutive patients (Society of Thoracic Surgeons score 18.5 ± 15.3, age 80 ± 8 years) who underwent transapical TAVI with Edwards Sapien valves between April 2008 and March 2011. Effective orifice area was calculated using the continuity equation and indexed with body surface area (iEOA). P-PM was stratified as severe (iEOA < 0.65 cm(2)/cm(2)) and moderate (iEOA, 0.65-0.85 cm(2)/m(2)). Midterm survival (up to 30 months) was analyzed by Kaplan-Meier curves and log-rank tests. There was no P-PM in 181 (65.1%) patients; moderate P-PM was found in 76 (27.3%) patients and severe P-PM in 21 (7.6%). Thirty-day survival was 96.0%, 97.3%, and 90.5%. The 3-month survival was 91%, 90%, and 66%, respectively (P = .0013). Combination of severe P-PM with peak pressure gradients greater than 10 mm Hg further reduced the 3-month survival to 48%. Additionally, mean survival time in patients with an ejection fraction less than 50% was significantly shorter than in patients with an ejection fraction greater than 50% (20.8 ± 1.5 vs 24.1 ± 0.8 months; P = .027).

Conclusions: P-PM is found in patients undergoing transapical TAVI. Severe mismatch is accompanied by high early mortality, especially when combined with increased pressure gradients.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / therapy*
  • Aortic Valve* / diagnostic imaging
  • Aortic Valve* / physiopathology
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cardiac Catheterization / mortality
  • Chi-Square Distribution
  • Echocardiography, Doppler
  • Echocardiography, Transesophageal
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Multivariate Analysis
  • Proportional Hazards Models
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Severity of Illness Index
  • Stroke Volume
  • Time Factors
  • Treatment Outcome
  • Ventricular Function, Left