Echocardiographic predictors of single versus dual MitraClip device implantation and long-term reduction of mitral regurgitation after percutaneous repair

Catheter Cardiovasc Interv. 2013 Oct 1;82(4):673-9. doi: 10.1002/ccd.24645. Epub 2013 Mar 14.

Abstract

Objectives: To describe predictors of the number of MitraClip devices implanted during percutaneous repair of mitral regurgitation (MR), and the long-term reduction in MR.

Background: In the EVEREST trials, one or two MitraClip devices were implanted to reduce MR, as needed.

Methods: Preprocedural transthoracic echocardiograms (TTE) and transesophageal echocardiograms (TEE) of 233 subjects who received 1 or 2 MitraClip devices in the EVEREST II Randomized Trial and High-Risk Study were analyzed. TEEs were reviewed for etiology of MR and pathoanatomic features of the valve, valve apparatus, and the regurgitant jet. Follow-up MR was assessed by TTE postprocedure and at 12 months.

Results: Ninety-seven subjects (42%) had two MitraClip devices implanted. Subjects with quantitatively more severe MR were more likely to receive two devices [mean regurgitant volume (RV) 45.9 ± 21.9 vs. 36.3 ± 18.5 mL, P <0.001]. On multivariate analysis, increased anterior leaflet thickness (OR 1.7 per mm, P = 0.007) and greater baseline RV (OR 1.21 per 10 mL, P = 0.01) were associated with increased odds of implanting two devices. The frequency of 2+ MR or less at discharge was similar regardless of the number of devices implanted. After propensity matching, patients had quantitatively similar MR at twelve-month follow-up, regardless of whether one or two MitraClip devices were implanted (P = 0.6).

Conclusions: Subjects with thicker anterior mitral leaflets and more severe MR were more likely to receive two MitraClip devices. Immediate and long-term reduction in MR was similar regardless of the number of devices implanted at the time of the procedure.

Keywords: hemodynamics; transeptal cath; valvular heart disease.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cardiac Catheterization / instrumentation*
  • Chi-Square Distribution
  • Echocardiography, Transesophageal*
  • Female
  • Humans
  • Logistic Models
  • Male
  • Middle Aged
  • Mitral Valve / diagnostic imaging*
  • Mitral Valve / physiopathology
  • Mitral Valve Insufficiency / diagnostic imaging*
  • Mitral Valve Insufficiency / physiopathology
  • Mitral Valve Insufficiency / therapy*
  • Multivariate Analysis
  • Odds Ratio
  • Predictive Value of Tests
  • Propensity Score
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Treatment Outcome