Objectives: To describe predictors of the number of MitraClip devices implanted during percutaneous repair of mitral regurgitation (MR), and the long-term reduction in MR.
Background: In the EVEREST trials, one or two MitraClip devices were implanted to reduce MR, as needed.
Methods: Preprocedural transthoracic echocardiograms (TTE) and transesophageal echocardiograms (TEE) of 233 subjects who received 1 or 2 MitraClip devices in the EVEREST II Randomized Trial and High-Risk Study were analyzed. TEEs were reviewed for etiology of MR and pathoanatomic features of the valve, valve apparatus, and the regurgitant jet. Follow-up MR was assessed by TTE postprocedure and at 12 months.
Results: Ninety-seven subjects (42%) had two MitraClip devices implanted. Subjects with quantitatively more severe MR were more likely to receive two devices [mean regurgitant volume (RV) 45.9 ± 21.9 vs. 36.3 ± 18.5 mL, P <0.001]. On multivariate analysis, increased anterior leaflet thickness (OR 1.7 per mm, P = 0.007) and greater baseline RV (OR 1.21 per 10 mL, P = 0.01) were associated with increased odds of implanting two devices. The frequency of 2+ MR or less at discharge was similar regardless of the number of devices implanted. After propensity matching, patients had quantitatively similar MR at twelve-month follow-up, regardless of whether one or two MitraClip devices were implanted (P = 0.6).
Conclusions: Subjects with thicker anterior mitral leaflets and more severe MR were more likely to receive two MitraClip devices. Immediate and long-term reduction in MR was similar regardless of the number of devices implanted at the time of the procedure.
Keywords: hemodynamics; transeptal cath; valvular heart disease.