Diagnostic ability and factors affecting accuracy of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid lesions: Japanese large single center experience

J Gastroenterol. 2013 Aug;48(8):973-81. doi: 10.1007/s00535-012-0695-8. Epub 2012 Oct 24.

Abstract

Background: Several studies have investigated the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for pancreatic lesions, but they have included only limited patient populations. This study aimed to clarify the diagnostic accuracy of EUS-FNA in a large number of pancreatic lesions, and to describe the factors that influence it.

Methods: From March 1997 to May 2010, 944 consecutive patients who had undergone EUS-FNA for pancreatic solid lesions were evaluated retrospectively. Factors affecting EUS-FNA accuracy were then analyzed.

Results: A total of 996 solid pancreatic lesions were sampled by EUS-FNA. The overall sampling adequacy and diagnostic accuracy of these lesions were 99.3 % (989/996) and 91.8 % (918/996), respectively. The sensitivity and specificity for differentiating malignant from benign lesions were 91.5 % (793/867) and 97.7 % (126/129), respectively. The diagnostic performance was significantly higher when both cytological and cell-block examinations were carried out than with only cytological examination. In multivariate analysis, final diagnosis, location of lesion, lesion size, availability of on-site cytopathological evaluation, and experience of EUS-FNA procedure were independent factors affecting the accuracy of EUS-FNA. On-site cytopathological evaluation and lesion size were found to be the most weighted factors affecting diagnostic accuracy.

Conclusions: EUS-FNA for pancreatic solid lesions yielded a high accuracy and low complication rate. Both cytological and cell-block preparations and on-site cytopathological evaluation contributed to improve the accuracy. The diagnostic ability of EUS-FNA was less for smaller lesions, and repeated procedures may be needed if malignancy is suspected.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration / methods*
  • Female
  • Humans
  • Japan
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Pancreatic Diseases / diagnosis*
  • Pancreatic Diseases / pathology
  • Pancreatic Neoplasms / diagnosis*
  • Pancreatic Neoplasms / pathology
  • Predictive Value of Tests
  • Retrospective Studies
  • Sensitivity and Specificity
  • Young Adult