Reproducibility of non-invasive assessment of skin endothelial function using laser Doppler flowmetry and laser speckle contrast imaging

PLoS One. 2013 Apr 19;8(4):e61320. doi: 10.1371/journal.pone.0061320. Print 2013.

Abstract

Background: Endothelial dysfunction precedes atherosclerosis. Vasodilation induced by acetylcholine (ACh) is a specific test of endothelial function. Reproducibility of laser techniques such as laser-Doppler-flowmetry (LDF) and Laser-speckle-contrast-imaging (LSCI) to detect ACh vasodilation is debated and results expressions lack standardization. We aimed to study at a 7-day interval (i) the inter-subject reproducibility, (ii) the intra-subjects reproducibility, and (iii) the effect of the results expressions over variability.

Methods and results: Using LDF and LSCI simultaneously, we performed two different ACh-iontophoresis protocols. The maximal ACh vasodilation (peak-ACh) was expressed as absolute or normalized flow or conductance values. Inter-subject reproducibility was expressed as coefficient of variation (inter-CV,%). Intra-subject reproducibility was expressed as within subject coefficients of variation (intra-CV,%), and intra-class correlation coefficients (ICC). Fifteen healthy subjects were included. The inter-subject reproducibility of peak-ACh depended upon the expression of the results and ranged from 55% to 162% for LDF and from 17% to 83% for LSCI. The intra-subject reproducibility (intra-CV/ICC) of peak-ACh was reduced when assessed with LSCI compared to LDF no matter how the results were expressed and whatever the protocol used. The highest intra-subject reproducibility was found using LSCI. It was 18.7%/0.87 for a single current stimulation (expressed as cutaneous vascular conductance) and 11.4%/0.61 for multiple current stimulations (expressed as absolute value).

Conclusion: ACh-iontophoresis coupled with LSCI is a promising test to assess endothelial function because it is reproducible, safe, and non-invasive. N°: NCT01664572.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acetylcholine / administration & dosage
  • Acetylcholine / pharmacology
  • Adult
  • Contrast Media*
  • Diagnostic Imaging / methods*
  • Endothelium, Vascular / drug effects
  • Endothelium, Vascular / physiology*
  • Female
  • Humans
  • Iontophoresis
  • Laser-Doppler Flowmetry / methods*
  • Male
  • Reproducibility of Results
  • Skin / blood supply*
  • Skin / drug effects
  • Vasodilation / drug effects

Substances

  • Contrast Media
  • Acetylcholine

Associated data

  • ClinicalTrials.gov/NCT01664572

Grants and funding

The study was supported in part by an “INTERFACE” grant from the “Institut National de la Santé et de la Recherche Médicale” (INSERM) and was promoted by the University Hospital of Angers. No additional external funding was received for this study. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.