Gadoxetic acid disodium-enhanced magnetic resonance imaging for the detection of hepatocellular carcinoma: a meta-analysis

PLoS One. 2013 Aug 15;8(8):e70896. doi: 10.1371/journal.pone.0070896. eCollection 2013.

Abstract

Objective: To determine the accuracy of MR imaging with gadoxetic acid disodium (Gd-EOB-DTPA) for the detection of hepatocelluar carcinoma (HCC).

Materials and methods: A systematic search was performed in PUBMED, EMBASE, Web of Science, Cochrane Library and the Chinese Biomedical Literature Database up to March 2013 to identify studies about evaluation of Gd-EOB-DTPA enhanced MR imaging in patients suspected of having HCC. The data were extracted to perform heterogeneity test and threshold effect test and to calculate sensitivity, specificity, diagnostic odds ratio, predictive value, and areas under summary receiver operating characteristic curve (AUC).

Results: From 601 citations, 10 were included in the meta-analysis. The methodological quality of the 10 studies was good. Overall HCC: There was significant heterogeneity in the pooled analysis (I(2) = 69.4%, P = 0.0005), and the pooled weighted values were determined to be sensitivity: 0.91 (95% confidence interval (CI): 0.89, 0. 93); specificity: 0.95 (95% CI: 0.94, 0.96); diagnostic odds ratio: 169.94 (95% CI: 108.84, 265.36); positive likelihood ratio: 15.75 (95% CI: 7.45, 33.31); negative likelihood ratio: 0.10 (95% CI: 0.06, 0.15). The AUC was 0.9778. HCC in cirrhosis: The estimates were to be sensitivity: 0.91 (95% CI: 0.88, 0.93); specificity: 0.93 (95% CI: 0.89, 0.95); diagnostic odds ratio: 234.24 (95% CI: 33.47, 1639.25); positive likelihood ratio: 15.08 (95% CI: 2.20, 103.40); negative likelihood ratio: 0.08 (95% CI: 0.03, 0.21). The AUC was 0.9814. ≤20 mm HCC: The AUC was 0.9936. There was no notable publication bias.

Conclusions: This meta-analysis suggests that MR imaging with Gd-EOB-DTPA has high diagnostic accuracy for the detection of HCC, especially for ≤20 mm HCC. This technique shows good prospect in diagnosis of HCC.

Publication types

  • Meta-Analysis

MeSH terms

  • Carcinoma, Hepatocellular / diagnosis*
  • Contrast Media*
  • Gadolinium DTPA*
  • Humans
  • Liver Neoplasms / diagnosis*
  • Magnetic Resonance Imaging*