Angle stable nails provide improved healing for a complex fracture model in the femur

Clin Orthop Relat Res. 2014 Apr;472(4):1300-9. doi: 10.1007/s11999-013-3288-9. Epub 2013 Sep 19.

Abstract

Background: Conventional nails are being used for an expanding range of fractures from simple to more complex. Angle stable designs are a relatively new innovation; however, it is unknown if they will improve healing for complex fractures.

Questions/purposes: When comparing traditional and angle stable nails to treat complex open canine femur fractures, the current study addressed the following questions: do the two constructs differ in (1) radiographic evidence of bone union across the cortices; (2) stability as determined by toggle (torsional motion with little accompanying torque) and angular deformation; (3) biomechanical properties, including stiffness in bending, axial compression, and torsional loading, and construct failure properties in torsion; and (4) degree of bone tissue mineralization?

Methods: Ten hounds with a 1-cm femoral defect and periosteal stripping were treated with a reamed titanium angle stable or nonangle stable nail after the creation of a long soft tissue wound. Before the study, the animals were randomly assigned to receive one of the nails and to be evaluated with biomechanical testing or histology. After euthanasia at 16 weeks, all operative femora were assessed radiographically. Histological or biomechanical evaluation was conducted of the operative bones with nails left in situ compared with the nonoperative contralateral femora.

Results: Radiographic and gross inspection demonstrated hypertrophic nonunion in all 10 animals treated with the nonangle stable nail, whereas six of 10 animals treated with the angle stable nail bridged at least one cortex (p = 0.023). The angle stable nail construct demonstrated no toggle in nine of 10 animals, whereas all control femora exhibited toggle. The angle stable nail demonstrated less angular deformation and toggle (p ≤ 0.005) and increased compressive stiffness (p = 0.001) compared with the conventional nonangle stable nail. Histology demonstrated more nonmineralized tissue in the limbs treated with the conventional nail (p = 0.005).

Conclusions: Angle stable nails that eliminate toggle lead to enhanced yet incomplete fracture healing in a complex canine fracture model.

Clinical relevance: Care should be taken in tailoring the nail design features to the characteristics of the fracture and the patient.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Animals
  • Biomechanical Phenomena
  • Bone Nails*
  • Disease Models, Animal
  • Dogs
  • Femoral Fractures / diagnostic imaging
  • Femoral Fractures / pathology
  • Femoral Fractures / physiopathology
  • Femoral Fractures / surgery*
  • Femur / diagnostic imaging
  • Femur / pathology
  • Femur / physiopathology
  • Femur / surgery*
  • Fracture Fixation, Internal / instrumentation*
  • Fracture Healing*
  • Male
  • Prosthesis Design
  • Radiography
  • Stress, Mechanical
  • Time Factors
  • Titanium
  • Torque
  • Weight-Bearing

Substances

  • Titanium