Value of fusion of PET and MRI in the detection of intra-pelvic recurrence of gynecological tumor: comparison with 18F-FDG contrast-enhanced PET/CT and pelvic MRI

Ann Nucl Med. 2014 Jan;28(1):25-32. doi: 10.1007/s12149-013-0777-6. Epub 2013 Oct 16.

Abstract

Background: To evaluate the diagnostic value of retrospective image fusion from pelvic magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography (PET) in detecting intra-pelvic recurrence of gynecological tumor.

Methods: Thirty patients with a suspicion of recurrence of gynecological malignancy underwent inline contrast-enhanced PET/computed tomography (CT) and pelvic contrast-enhanced MRI for restaging. Diagnostic performance about the local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion of PET/low-dose non-enhanced CT (PET/ldCT), PET/full-dose contrast-enhanced CT (PET/ceCT), contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) were evaluated by two experienced readers. Final diagnoses were obtained by histopathological examinations, radiological imaging and clinical follow-up for at least 6 months. McNemar test was employed for statistical analysis.

Results: Documented positive locally recurrent disease, pelvic lymph node and bone metastases, and peritoneal dissemination were present in 53.3, 26.7, 10.0, and 16.7%, respectively. Patient-based sensitivity for detecting local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion were 87.5, 87.5, 100 and 80.0%, respectively, for fused PET/MRI, 87.5, 62.5, 66.7 and 60.0%, respectively, for contrast-enhanced MRI, 62.5, 87.5, 66.7 and 80.0%, respectively, for PET/ceCT, and 50.0, 87.5, 66.7 and 60.0%, respectively, for PET/ldCT. The sensitivity of diagnosing local recurrence by fused PET/MRI was significantly better than that of PET/ldCT (p=0.041). The patient-based sensitivity, specificity and accuracy for the detection of intra-pelvic recurrence/metastasis were 91.3, 100 and 93.3% for fused PET/MRI, 82.6, 100 and 86.7% for contrast-enhanced MRI, 82.6, 100 and 86.7% for PET/ceCT and 78.3, 85.7 and 80.0% for PET/ldCT.

Conclusion: Fused PET/MRI combines the individual advantages of MRI and PET, and is a valuable technique for assessment of intra-pelvic recurrence of gynecological cancers.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media
  • Female
  • Fluorodeoxyglucose F18*
  • Humans
  • Image Processing, Computer-Assisted*
  • Magnetic Resonance Imaging*
  • Middle Aged
  • Multimodal Imaging
  • Neoplasm Recurrence, Local / diagnosis*
  • Neoplasm Recurrence, Local / diagnostic imaging
  • Pelvis*
  • Positron-Emission Tomography*
  • Retrospective Studies
  • Tomography, X-Ray Computed
  • Urogenital Neoplasms / diagnosis*
  • Urogenital Neoplasms / diagnostic imaging

Substances

  • Contrast Media
  • Fluorodeoxyglucose F18