Expanded measurements of intra-abdominal pressure do not increase the detection rate of intra-abdominal hypertension: a single-center observational study

Crit Care Med. 2014 Feb;42(2):378-86. doi: 10.1097/CCM.0b013e3182a6459b.

Abstract

Objective: Intra-abdominal hypertension may contribute to a poor outcome. Whether limiting intra-abdominal pressure measurements to preselected at-risk patients allows for sufficient detection of intra-abdominal hypertension is unclear. We aimed to clarify whether expanded intra-abdominal pressure monitoring results in an increased detection rate of intra-abdominal hypertension.

Design: Retrospective observational study.

Setting: General ICU of University Hospital.

Patients: Consecutive adult ICU patients from 2004 to 2011.

Interventions: Intra-abdominal pressure measurements in predefined at-risk patients.

Measurements and main results: Prospectively collected data of 2,696 admissions were divided into three subgroups according to the intra-abdominal pressure measurement policy in different years: 1) 2004-2005, mechanically ventilated patients with at least one additional risk factor for intra-abdominal hypertension (multiple trauma, abdominal surgery, pancreatitis, post-cardiopulmonary resuscitation, fluid resuscitation > 5 L/24 hr, vasoactive or inotropic support, and renal replacement therapy); 2) 2006-2009, all mechanically ventilated patients expected to stay for more than or equal to 24 hours; and 3) 2010-2011, mechanically ventilated patients with a body mass index greater than 30 kg/m, positive end-expiratory pressure more than 10 cm H2O, PaO2/FIO2 less than 300, use of vasopressors/inotropes, pancreatitis, hepatic failure/cirrhosis with ascites, gastrointestinal bleeding, or postlaparotomy. In all, 2,696 patients were studied, and 1,241 patients (46.0%) underwent intra-abdominal pressure monitoring. The intra-abdominal pressure was measured in 31.7%, 55.6%, and 41.1% of patients during the first, second, and third time periods (p < 0.001), and intra-abdominal hypertension (intra-abdominal pressure ≥ 12 mm Hg) occurred in 19.9%, 20.3%, and 20.1% of patients, respectively (p = 0.972). The mean intra-abdominal pressure at admission day was an independent predictor of mortality in patients with intra-abdominal pressure measurements started within the first 24 hours (odds ratio, 1.046 [95% CI, 1.019-1.072]). The mortality of patients with intra-abdominal hypertension was 29.8% versus 18.6% in those without intra-abdominal hypertension (p < 0.001).

Conclusions: Expanding the measurement of intra-abdominal pressure to more than 50% of intensive care admissions does not increase the detection rate of intra-abdominal hypertension. In patients with intra-abdominal pressure monitoring, the mean intra-abdominal pressure on the admission day is an independent predictor of mortality.

Publication types

  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Diagnostic Techniques, Cardiovascular
  • Female
  • Humans
  • Intra-Abdominal Hypertension / diagnosis*
  • Male
  • Middle Aged
  • Retrospective Studies
  • Young Adult