Supra-aortic arteries: three-dimensional time-resolved k-t BLAST contrast-enhanced MRA using a nondedicated body coil at 3 tesla in acute ischemic stroke

J Magn Reson Imaging. 2014 Nov;40(5):1056-63. doi: 10.1002/jmri.24466. Epub 2013 Nov 12.

Abstract

Purpose: To assess the image quality and diagnostic performance achieved by using supra-aortic 3D-TR-CE-k-t BLAST MRA and a nondedicated body coil as compared with conventional CE-MRA in patients with acute ischemic stroke.

Materials and methods: In this prospective study, 36 consecutive patients with a suspected acute ischemic stroke underwent both k-t BLAST MRA and conventional CE-MRA. Image quality was assessed using visual and quantitative criteria and the techniques were compared. Both techniques were compared for degree of visual and quantitative measurement of carotid stenosis.

Results: Delineation of vessel lumen and overall diagnostic confidence were significantly better with CE-MRA, respectively 3.4 ± 0.5 and 3.3 ± 0.6 (mean score ± SD), than with k-t BLAST MRA, respectively 2.8 ± 0.4 and 2.9 ± 0.5 (P < 0.02). SNR and CNR were significantly higher for k-t BLAST MRA, respectively 33.5 ± 19.3 and 27.9 ± 19.3, than for CE-MRA, respectively 25.7 ± 10 and 20.4 ± 8.4 (P < 0.03). Intertechnique agreement was good for carotid stenosis characterization (κ = .763). For the 14 relevant stenosis, stenosis measurements were highly correlated between techniques (0.96; P < 0.0001). The Bland-Altman plot showed a low bias in assessment of the degree of stenosis (mean bias 2.1% ± 7.7).

Conclusion: k-t BLAST MRA using a nondedicated coil offering and dynamic information was a effective diagnostic tool for detection and characterization of carotid stenosis.

Keywords: MRA; contrast-enhanced MRA; stroke; time-resolved.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Aortography / instrumentation
  • Aortography / methods*
  • Brain Infarction / diagnosis*
  • Carotid Stenosis / diagnosis*
  • Cerebral Angiography / instrumentation
  • Cerebral Angiography / methods*
  • Contrast Media*
  • Female
  • Humans
  • Image Enhancement / instrumentation
  • Image Enhancement / methods*
  • Image Interpretation, Computer-Assisted / methods
  • Imaging, Three-Dimensional / instrumentation
  • Imaging, Three-Dimensional / methods*
  • Magnetic Resonance Angiography / instrumentation
  • Magnetic Resonance Angiography / methods*
  • Male
  • Meglumine*
  • Middle Aged
  • Organometallic Compounds*
  • Prospective Studies
  • Sensitivity and Specificity

Substances

  • Contrast Media
  • Organometallic Compounds
  • Meglumine
  • gadoterate meglumine