Misplacement of a right internal jugular hemodialysis catheter in a persistent left superior vena cava

J Clin Anesth. 2014 Feb;26(1):84-5. doi: 10.1016/j.jclinane.2013.07.012. Epub 2014 Jan 15.
No abstract available

Publication types

  • Case Reports
  • Letter

MeSH terms

  • Adult
  • Catheterization / instrumentation*
  • Catheterization / methods
  • Contrast Media
  • Humans
  • Jugular Veins / diagnostic imaging*
  • Kidney Failure, Chronic / therapy
  • Male
  • Medical Errors*
  • Microbubbles
  • Phlebography / methods
  • Renal Dialysis / instrumentation*
  • Ultrasonography
  • Vena Cava, Superior / abnormalities
  • Vena Cava, Superior / diagnostic imaging*

Substances

  • Contrast Media