Background: The sine-wave-shaped skin incision is a technique that minimizes skin-related complications near burr hole caps after electrode placement for deep-brain stimulation (DBS).
Methods: Between 2011 and 2013, 54 DBS electrodes were implanted in 27 consecutive patients with Parkinson's disease (PD), essential tremor, or dystonia. The sine-wave incision was used in 26 patients and conventional bilateral linear scalp incisions were used in one patient.
Results: None of the patients whose operations involved sine-wave-shaped incisions developed hardware-linked complications such as skin infection or skin erosion. The one patient who underwent conventional bilateral linear scalp incisions developed a skin infection.
Conclusion: By preserving the vascular anatomy of the scalp and reducing skin tension at the wound site, the sine-wave-shaped incision promotes wound healing.