Diffusion-weighted magnetic resonance imaging using different b-value combinations for the evaluation of treatment results after volumetric MR-guided high-intensity focused ultrasound ablation of uterine fibroids

Eur Radiol. 2014 Sep;24(9):2118-27. doi: 10.1007/s00330-014-3274-y. Epub 2014 Jun 25.

Abstract

Objectives: To assess the value of diffusion-weighted magnetic resonance imaging (DWI) and apparent diffusion coefficient (ADC) mapping using different b-value combinations for treatment evaluation after magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) of uterine fibroids.

Methods: Fifty-six patients with 67 uterine fibroids were treated with volumetric MR-HIFU. Pre-treatment and post-treatment images were obtained using contrast-enhanced T1-weighted MRI (CE-T1WI) and DWI using b = 0, 200, 400, 600, 800 s/mm(2). ADC maps were generated using subsets of b-values to investigate the effects of tissue ablation on water diffusion and perfusion in fibroids treated with MR-HIFU. Four combinations of b-values were used: (1) all b-values; (2) b = 0, 200 s/mm(2); (3) b = 400, 600, 800 s/mm(2); and (4) b = 0, 800 s/mm(2).

Results: Using the lowest b-values (0 and 200 s/mm(2)), the mean ADC value in the ablated tissue reduced significantly (p < 0.001) compared with baseline. Calculating the ADC value with the highest b-values (400, 600, 800 s/mm(2)), the ADC increased significantly (p < 0.001) post-treatment. ADC maps calculated with the lowest b-values resulted in the best visual agreement of non-perfused fibroid tissue detected on CE images. Other b-value combinations and normal myometrium showed no difference in ADC after MR-HIFU treatment.

Conclusions: A decrease in contrast agent uptake within the ablated region on CE-T1WI was correlated to a significantly decreased ADC when b = 0 and 200 s/mm(2) were used.

Key points: DWI could be useful for treatment evaluation after MR-HIFU of uterine fibroids. The ADC in fibroid tissue is influenced by the choice of b- values. Low b-values seem the best choice to emphasise perfusion effects after MR-HIFU.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • High-Intensity Focused Ultrasound Ablation / methods*
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Leiomyoma / pathology
  • Leiomyoma / surgery*
  • Myometrium / pathology
  • ROC Curve
  • Reproducibility of Results
  • Surgery, Computer-Assisted / methods*
  • Treatment Outcome
  • Tumor Burden
  • Uterine Neoplasms / pathology
  • Uterine Neoplasms / surgery*