Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase

AJR Am J Roentgenol. 2014 Sep;203(3):601-6. doi: 10.2214/AJR.13.11337.

Abstract

Objective: The purpose of this study was to evaluate the effect of use of dual-energy CT monochromatic imaging in the late hepatic arterial phase on hyperenhancing focal lesion detection and lesion conspicuity.

Subjects and methods: This prospective study included 72 patients imaged with a single-source dual-energy CT scanner. Late arterial phase imaging was performed with dual energies of 140 and 80 kVp, and the portal venous and delayed phases were performed with a single energy of 120 kVp. Two deidentified image sets were created: set A consisted of 77-keV images only, and set B consisted of 40-, 50-, 70-, and 77-keV images and iodine-based contrast material decomposition images. Two independent reviewers identified hypervascular lesions and subjectively scored lesion conspicuity. Contrast-to-noise ratios were calculated, and radiation dose (volume CT dose index) was recorded.

Results: The 128 lesions identified had a mean size of 1.7 ± 1.4 cm. There was no difference in lesion detection between the two reviewers or the two image sets. The contrast-to-noise ratio at 50 keV was 72% greater than that at 77 keV (p < 0.0001). Subjective conspicuity was statistically greatest at 50 keV (p < 0.0001). There was no statistical difference in mean volume CT dose index between the dual-energy (12.8 mGy) and the two single-energy (14.4 and 14.2 mGy) phases.

Conclusion: Viewing dual-energy CT images may result in the greatest subjective lesion conspicuity and measured contrast-to-noise ratio at 50 keV with equal detection of hyperenhancing liver lesions compared with viewing 77-keV images alone. In addition, the radiation doses of dual-energy CT may be similar to those of single-energy CT.

Keywords: cirrhosis; dual-energy CT; fast kilovoltage switching; hepatocellular carcinoma; liver CT.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Female
  • Humans
  • Liver Cirrhosis / complications
  • Liver Cirrhosis / diagnostic imaging*
  • Liver Neoplasms / blood supply
  • Liver Neoplasms / diagnostic imaging*
  • Liver Neoplasms / etiology
  • Male
  • Middle Aged
  • Neovascularization, Pathologic / diagnostic imaging*
  • Neovascularization, Pathologic / etiology
  • Observer Variation
  • Portal Vein / diagnostic imaging
  • Precancerous Conditions / diagnostic imaging*
  • Radiographic Image Enhancement / methods
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Radiography, Dual-Energy Scanned Projection / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Signal-To-Noise Ratio
  • Tomography, X-Ray Computed / methods