Access path angle in transapical aortic valve replacement: risk factor for paravalvular leakage

Ann Thorac Surg. 2014 Nov;98(5):1572-8. doi: 10.1016/j.athoracsur.2014.06.055. Epub 2014 Sep 18.

Abstract

Background: The aim of this study was to analyze the angle between the left ventricular (LV) long axis and the LV outflow tract (αLV-LVOT) on cardiac computed tomography and to describe its effect on the occurrence of paravalvular leakage (PL), fluoroscopy time, and postoperative creatine kinase-MB levels in transapical transcatheter aortic valve replacement (TA-TAVR).

Methods: High-risk patients with severe aortic stenosis scheduled for TA-TAVR using an Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis were retrospectively included. The αLV-LVOT was measured during systole and diastole as far as retrospectively gated data sets were available. The αLV-LVOT was correlated with the occurrence of PL, total fluoroscopy time, and postoperative creatine kinase-MB levels. Interobserver variability was assessed in all cases.

Results: The study included 81 patients (57 women [70.4%], 24 men [29.6%]) with an average age of 81.9±5.8 years. The mean αLV-LVOTs were 61.8±9.9 degrees during systole and 61.1±10.0 degrees during diastole. There was a minimal, nonsignificant change in the αLV-LVOT between systole and diastole of 0.2±4.1 degrees (p=0.7). PL was found in 39 patients: grade 0 in 42 (51.9%), grade I in 30 (37.0%), and grade II in 9 (11.1%). Patients with a clinically significant PL (grade≥II) showed a significantly greater mean αLV-LVOT than patients with grade I or without PL (mean difference, 13.8±3.2 degrees; p<0.001). No significant correlation was found between the αLV-LVOT and total fluoroscopy time (r=-0.17, p=0.16) and postoperative creatine kinase-MB levels (r=-0.1, p=0.44).

Conclusions: During TA-TAVR, greater αLV-LVOTs were associated with significantly higher grades of PL. Thus, the αLV-LVOT might influence the selection of the transapical implantation path and could have a significant effect on designs for future stents or novel delivery devices.

MeSH terms

  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / surgery*
  • Aortography
  • Echocardiography, Doppler, Color
  • Echocardiography, Transesophageal
  • Electrocardiography
  • Female
  • Fluoroscopy
  • Follow-Up Studies
  • Germany / epidemiology
  • Heart Valve Prosthesis*
  • Humans
  • Incidence
  • Male
  • Multidetector Computed Tomography
  • Postoperative Complications / diagnosis
  • Postoperative Complications / epidemiology*
  • Prosthesis Design
  • Retrospective Studies
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Transcatheter Aortic Valve Replacement / methods*