Characterization of prostate cancer using T2 mapping at 3T: a multi-scanner study

Diagn Interv Imaging. 2015 Apr;96(4):365-72. doi: 10.1016/j.diii.2014.11.016. Epub 2014 Dec 23.

Abstract

Rationale and objectives: To assess the prostate T2 value as a predictor of malignancy on two different 3T scanners.

Patients and methods: Eighty-three pre-prostatectomy multiparametric MRIs were retrospectively evaluated [67 obtained on a General Electric MRI (scanner 1) and 16 on a Philips MRI (scanner 2)]. After correlation with prostatectomy specimens, readers measured the T2 value of regions-of-interest categorized as "cancers", "false positive lesions", or "normal tissue".

Results: On scanner 1, in PZ, cancers had significantly lower T2 values than false positive lesions (P=0.02) and normal tissue (P=2×10(-9)). Gleason≥6 cancers had similar T2 values than false positive lesions and significantly higher T2 values than Gleason≥7 cancers (P=0.009). T2 values corresponding to a 25% and 75% risk of Gleason≥7 malignancy were respectively 132 ms (95% CI: 129-135 ms) and 77 ms (95% CI: 74-81 ms). In TZ, cancers had significantly lower T2 values than normal tissue (P=0.008), but not than false positive findings. Mean T2 values measured on scanner 2 were not significantly different than those measured on scanner 1 for all tissue classes.

Conclusion: All tested tissue classes had similar mean T2 values on both scanners. In PZ, the T2 value was a significant predictor of Gleason≥7 cancers.

Keywords: Prostate cancer; Prostate cancer aggressiveness; Prostate multiparametric MRI; T2.