Background: The negative predictive value of endoscopic ultrasonography-guided fine needle aspiration for the diagnosis of solid pancreatic lesions remains low, and the biopsy specimens are sometimes inadequate for appropriate pathological diagnosis.
Aims: To evaluate the usefulness of a novel method of contrast-enhanced harmonic endoscopic ultrasonography-guided fine-needle aspiration for the differential diagnosis and adequate sampling of solid pancreatic lesions.
Methods: Patients with a diagnosis of solid pancreatic lesions who underwent fine-needle aspiration guided by contrast-enhanced harmonic endoscopic ultrasonography or by endoscopic ultrasonography from October 2010 to July 2013 were retrospectively identified and classified into the CH-EUS or EUS group, respectively. Surgical pathology and/or follow-up results were defined as the final diagnosis. Operating characteristics and adequacy of biopsy specimens by fine-needle aspiration were compared between the two groups.
Results: Operating characteristics for contrast-enhanced harmonic endoscopic ultrasonography-guided fine-needle aspiration in solid pancreatic lesions were as follows: area under the curve = 0.908, sensitivity = 81.6%, specificity = 100%, positive predictive value = 100%, negative predictive value = 74.1%, and accuracy = 87.9%. The percentage of adequate biopsy specimens in the CH-EUS group (96.6%) was greater than that in the EUS group (86.7%).
Conclusion: Simultaneous contrast-enhanced harmonic endoscopic ultrasonography during fine-needle aspiration is useful for improving the diagnostic yield and adequate sampling of solid pancreatic lesions.