Background: Fecal antigen detection using the enzyme linked immunosorbent assay (ELISA) and oocyst detection using auramine phenol (AP) staining methods, are told to be more sensitive compared to other conventional methods, for diagnosis of cryptosporidiosis.
Objectives: The aim of the present study was to evaluate the antigen-detection capacity in the stool specimens using ELISA and oocyst detection by AP staining methods, for the diagnosis of human cryptosporidiosis.
Materials and methods: A total of 228 fecal samples were collected from residents of rural areas of Hamadan, West of Iran. Each fecal sample was divided into two parts, one kept frozen at -20˚C for Ag-capture ELISA and the other in 10% formalin for the AP staining method. Cryptosporidium Ag-detection ELISA procedure was performed according to the manual of the manufacturer. The preserved samples concentrated using the formalin-ether concentration technique were stained with AP and then investigated under florescent microscopy.
Results: Eight (3.5%) and three (1.3%) out of 228 fecal samples were positive for Cryptosporidium infection by ELISA and AP staining methods, respectively. Cryptosporidium Ag-detection using ELISA showed an increased frequency of the infection, compared to the AP staining method (P = 0.062).
Conclusions: For epidemiological studies and diagnostic purposes of the Cryptosporidium infection, especially in asymptomatic individuals, Ag-detection ELISA is an easy to perform and accurate method, compared to other conventional microscopic methods.
Keywords: Auramine phenol; Cryptosporidium; Enzyme-Linked Immunosorbent Assay; Oocysts.