Surgical infrarenal "neo-neck" technique during elective conversion after EVAR with suprarenal fixation

Eur J Vasc Endovasc Surg. 2015 Aug;50(2):175-80. doi: 10.1016/j.ejvs.2015.03.027. Epub 2015 Apr 25.

Abstract

Objectives: Conversion of a previous endovascular aneurysm repair (EVAR) with suprarenal fixation is a challenging situation even in the elective setting. The outcomes of a technique based on preservation of the first proximal covered stent of the endograft, used as a "neo-neck" for proximal anastomosis, are presented.

Methods: From 2001 to 2014, nine patients underwent elective conversion of a previous suprarenally fixed EVAR. After supraceliac clamping, the aneurysm sac was opened and the endograft identified; the fabric was cut beyond the first covered stent together with its native aortic wall in order to create a "neo-neck." An aortic balloon was inflated into the visceral aorta to avoid back bleeding. A Dacron bifurcated tube graft (Intergard, Maquet) was then sutured to the neo-neck mimicking endobanding, passing the stitches into the aortic wall and the first covered stent.

Results: The mean age was 68 years (range, 52-84 years). The stent grafts removed were four Zenith (Cook Medical), three Endurant (Medtronic), and two E-vita (Jotec). The indication for conversion was type 1A (n = 2), type 2 (n = 2), and type 3 (n = 1) endoleak, complete endograft thrombosis (n = 2), and abdominal pain with sac enlargement with no radiological sign of endoleak (n = 2). Blood loss was 1,428 mL (range 500-3,000 mL); the visceral ischemic time to perform the proximal anastomosis was 23.5 min ± 2.3 min). The post-operative complication rate was 11% (n = 1/9) related to a case of sac wall bleeding requiring re-intervention; mortality at 30 days was 0%. At 22 months (range, 8-41) the computed tomography angiogram demonstrated no signs of leaks or anastomotic pseudoaneurysm.

Conclusion: Preservation of the proximal covered stent of an endograft with suprarenal fixation used as an infrarenal "neo-neck" with incorporation of the aorta to the suture line during elective surgical explantation simplifies the procedure, and can be achieved with very low early morbidity and mortality; furthermore, it seems to be durable over mid-term follow up.

Keywords: EVAR conversion; EVAR explantation; Failed EVAR; Hybrid aortic reconstruction.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnosis
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortography
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Device Removal* / adverse effects
  • Elective Surgical Procedures
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Female
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / diagnosis
  • Postoperative Complications / surgery*
  • Prosthesis Design
  • Reoperation
  • Retrospective Studies
  • Stents
  • Time Factors
  • Treatment Outcome