Compensatory UTE/T2W Imaging of Inflammatory Vascular Wall in Hyperlipidemic Rabbits

PLoS One. 2015 May 15;10(5):e0124572. doi: 10.1371/journal.pone.0124572. eCollection 2015.

Abstract

Objectives: To obtain compensatory ultra-short echo time (UTE) imaging and T2-weighted (T2W) imaging of Watanabe heritable hyperlipidemic (WHHL) rabbits following dextran-coated magnetic nanocluster (DMNC) injection for the effective in vivo detection of inflammatory vascular wall.

Methods: Magnetic nanoparticle was synthesized by thermal decomposition and encapsulated with dextran to prepare DMNC. The contrast enhancement efficiency of DMNC was investigated using UTE (repetition time [TR] = 5.58 and TE = 0.07 ms) and T2W (TR = 4000 and TE = 60 ms) imaging sequences. To confirm the internalization of DMNC into macrophages, DMNC-treated macrophages were visualized by cellular transmission electron microscope (TEM) and magnetic resonance (MR) imaging. WHHL rabbits expressing macrophage-rich plaques were subjected to UTE and T2W imaging before and after intravenous DMNC (120 μmol Fe/kg) treatment. Ex vivo MR imaging of plaques and immunostaining studies were also performed.

Results: Positive and negative contrast enhancement of DMNC solutions with increasing Fe concentrations were observed in UTE and T2W imaging, respectively. The relative signal intensities of the DMNC solution containing 2.9 mM Fe were calculated as 3.53 and 0.99 in UTE and T2W imaging, respectively. DMNC uptake into the macrophage cytoplasm was visualized by electron microscopy. Cellular MR imaging of DMNC-treated macrophages revealed relative signals of 3.00 in UTE imaging and 0.98 in T2W imaging. In vivo MR images revealed significant brightening and darkening of plaque areas in the WHHL rabbit 24 h after DMNC injection in UTE and T2W imaging, respectively. Ex vivo MR imaging results agreed with these in vivo MR imaging results. Histological analysis showed that DMNCs were localized to areas of inflammatory vascular wall.

Conclusions: Using compensatory UTE and T2W imaging in conjunction with DMNC is an effective approach for the noninvasive in vivo imaging of atherosclerotic plaque.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Cell Line
  • Contrast Media / chemistry
  • Macrophages
  • Magnetic Resonance Imaging / methods*
  • Magnetite Nanoparticles / chemistry
  • Male
  • Mice
  • Plaque, Atherosclerotic / diagnosis
  • Rabbits

Substances

  • Contrast Media
  • Magnetite Nanoparticles

Grants and funding

This study was supported by a grant of the Korea Healthcare technology R&D Project, Ministry for Health & Welfare Affairs, Republic of Korea (A085136) and Bio & Medical Technology Development Program of the National Research Foundation (NRF) funded by the Korean government (MEST)(2012050077) and National Research Foundation of Korea (NRF) grant funded by the Korea government (MEST) (No.2006-2004652) and Korea Healthcare Technology R&D Project, Ministry for Health, Welfare and Family Affairs, Republic of Korea (No.A102064). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.