Clinical and Analytical Evaluation of a Single-Vial Stool Collection Device with Formalin-Free Fixative for Improved Processing and Comprehensive Detection of Gastrointestinal Parasites

J Clin Microbiol. 2015 Aug;53(8):2539-48. doi: 10.1128/JCM.00838-15. Epub 2015 May 27.

Abstract

Microscopic examination of feces is a standard laboratory method for diagnosing gastrointestinal parasite infections. In North America, the ovum and parasite (O&P) examination is typically performed using stool that is chemically fixed in polyvinyl alcohol (PVA) and formalin, after which the stool is concentrated by filtration to enhance sensitivity. Mini Parasep solvent-free (SF) tubes allow collection and concentration within a single collection vial. The goal of the study was to determine whether consolidated processing and concentration with the Parasep tubes using an alcohol-based fixative (Alcorfix) provide O&P examinations equivalent to or better than those done by processing of PVA-formalin-fixed stool using a SpinCon concentration device. Parasep tubes revealed filtration performance equivalent to that of the SpinCon concentration device using PVA-formalin-fixed stool containing protozoa. Specimens cocollected in Parasep tubes containing PVA-formalin and Alcorfix revealed comparable morphology and staining for various protozoa. Alcorfix effectively fixed live Cryptosporidium and microsporidia such that morphology and staining were conserved for modified acid-fast and modified trichrome stains. A work flow analysis revealed significant time savings for batches of 10 or 30 O&P specimens in tubes with Alcorfix compared to the amount of time that it took to analyze the same number of specimens in tubes with PVA-formalin. The direct hands-on time savings with Mini Parasep tubes were 17 min and 41 s and 32 min and 1 s for batches of 10 and 30 specimens, respectively. Parasep tubes containing Alcorfix provide significant work flow advantages to laboratories that process medium to high volumes of O&P specimens by streamlining processing and converting to a single tube. These improvements in work flow, reduction of the amount of formalin used in the laboratory, and equivalent microscopy results are attractive advancements in O&P testing for North American diagnostic parasitology laboratories.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Animals
  • Feces / parasitology*
  • Humans
  • Intestinal Diseases, Parasitic / diagnosis*
  • Microscopy
  • North America
  • Parasites / isolation & purification*
  • Parasitology / methods
  • Sensitivity and Specificity
  • Specimen Handling / methods*
  • Time Factors
  • Workflow