Non-Enhanced MR Imaging of Cerebral Arteriovenous Malformations at 7 Tesla

Eur Radiol. 2016 Mar;26(3):829-39. doi: 10.1007/s00330-015-3875-0. Epub 2015 Jun 17.

Abstract

Objective: To evaluate prospectively 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) and 7 Tesla non-contrast-enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of intracerebral arteriovenous malformations (AVMs) in comparison to 1.5 Tesla TOF MRA and digital subtraction angiography (DSA).

Methods: Twenty patients with single or multifocal AVMs were enrolled in this trial. The study protocol comprised 1.5 and 7 Tesla TOF MRA and 7 Tesla non-contrast-enhanced MPRAGE sequences. All patients underwent an additional four-vessel 3D DSA. Image analysis of the following five AVM features was performed individually by two radiologists on a five-point scale: nidus, feeder(s), draining vein(s), relationship to adjacent vessels, and overall image quality and presence of artefacts.

Results: A total of 21 intracerebral AVMs were detected. Both sequences at 7 Tesla were rated superior over 1.5 Tesla TOF MRA in the assessment of all considered AVM features. Image quality at 7 Tesla was comparable with DSA considering both sequences. Inter-observer accordance was good to excellent for the majority of ratings.

Conclusion: This study demonstrates excellent image quality for depiction of intracerebral AVMs using non-contrast-enhanced 7 Tesla MRA, comparable with DSA. Assessment of untreated AVMs is a promising clinical application of ultra-high-field MRA.

Key points: • Non-contrast-enhanced 7 Tesla MRA demonstrates excellent image quality for intracerebral AVM depiction. • Image quality at 7 Tesla was comparable with DSA considering both sequences. • Assessment of intracerebral AVMs is a promising clinical application of ultra-high-field MRA.

Keywords: 7 Tesla; Arteriovenous malformation; MPRAGE; Magnetic resonance angiography; TOF MRA.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Angiography, Digital Subtraction / methods
  • Angiography, Digital Subtraction / standards
  • Artifacts
  • Female
  • Humans
  • Intracranial Arteriovenous Malformations / pathology*
  • Magnetic Resonance Angiography / methods
  • Magnetic Resonance Angiography / standards
  • Male
  • Middle Aged
  • Observer Variation
  • Sensitivity and Specificity
  • Young Adult