Evaluation of a consumer fitness-tracking device to assess sleep in adults

Chronobiol Int. 2015;32(7):1024-8. doi: 10.3109/07420528.2015.1054395.

Abstract

Wearable fitness-tracker devices are becoming increasingly available. We evaluated the agreement between Jawbone UP and polysomnography (PSG) in assessing sleep in a sample of 28 midlife women. As shown previously, for standard actigraphy, Jawbone UP had high sensitivity in detecting sleep (0.97) and low specificity in detecting wake (0.37). However, it showed good overall agreement with PSG with a maximum of two women falling outside Bland-Altman plot agreement limits. Jawbone UP overestimated PSG total sleep time (26.6 ± 35.3 min) and sleep onset latency (5.2 ± 9.6 min), and underestimated wake after sleep onset (31.2 ± 32.3 min) (p's < 0.05), with greater discrepancies in nights with more disrupted sleep. The low-cost and wide-availability of these fitness-tracker devices may make them an attractive alternative to standard actigraphy in monitoring daily sleep-wake rhythms over several days.

Keywords: Actigraphy; activity trackers; motion; sleep; wristbands.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Actigraphy / instrumentation*
  • Activity Cycles
  • Equipment Design
  • Female
  • Humans
  • Middle Aged
  • Polysomnography*
  • Predictive Value of Tests
  • Reproducibility of Results
  • Sleep*
  • Time Factors