Internal carotid artery rupture caused by carotid shunt insertion

Int J Surg Case Rep. 2015:14:89-91. doi: 10.1016/j.ijscr.2015.07.030. Epub 2015 Jul 31.

Abstract

Introduction: Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously.

Presentation of case: A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful.

Discussion: Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect.

Conclusion: Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA.