Enhanced Detection of Low-Abundance Host Cell Protein Impurities in High-Purity Monoclonal Antibodies Down to 1 ppm Using Ion Mobility Mass Spectrometry Coupled with Multidimensional Liquid Chromatography

Anal Chem. 2015 Oct 20;87(20):10283-91. doi: 10.1021/acs.analchem.5b02103. Epub 2015 Sep 10.

Abstract

The enormous dynamic range of proteinaceous species present in protein biotherapeutics poses a significant challenge for current mass spectrometry (MS)-based methods to detect low-abundance HCP impurities. Previously, an HCP assay based on two-dimensional chromatographic separation (high pH/low pH) coupled to high-resolution quadrupole time-of-flight (QTOF) mass spectrometry and developed in the author's laboratory has been shown to achieve a detection limit of about 50 ppm (parts per milion) for the identification and quantification of HCPs present in monoclonal antibodies following Protein A purification.1 To improve the HCP detection limit we have explored the utility of several new analytical techniques for HCP analysis and thereby developed an improved liquid chromatography-mass spectrometry (LC-MS) methodology for enhanced detection of HCPs. The new method includes (1) the use of a new charge-surface-modified (CSH) C18 stationary phase to mitigate the challenges of column saturation, peak tailing, and distortion that are commonly observed in the HCP analysis; (2) the incorporation of traveling-wave ion mobility (TWIM) separation of coeluting peptide precursors, and (3) the improvement of fragmentation efficiency of low-abundance HCP peptides by correlating the collision energy used for precursor fragmentation with their mobility drift time. As a result of these improvements, the detection limit of the new methodology was greatly improved, and HCPs present at a concentration as low as 1 ppm (1 ng HCP/mg mAb) were successfully identified and quantified. The newly developed method was applied to analyze two high-purity mAbs (NIST mAb and Infliximab) expressed in a murine cell line. For both samples, low-abundance HCPs (down to 1 ppm) were confidently identified, and the identities of the HCPs were further confirmed by targeted MS/MS experiments. In addition, the performance of the assay was evaluated by an interlaboratory study in which three independent laboratories performed the same HCP assay on the mAb sample. The reproducibility of this assay is also discussed.

MeSH terms

  • Animals
  • Antibodies, Monoclonal / chemistry*
  • Chromatography, Liquid
  • Drug Contamination*
  • Mass Spectrometry*
  • Mice
  • Proteins / analysis*

Substances

  • Antibodies, Monoclonal
  • Proteins