A novel drug-coated scoring balloon for the treatment of coronary in-stent restenosis: Results from the multi-center randomized controlled PATENT-C first in human trial

Catheter Cardiovasc Interv. 2016 Jul;88(1):51-9. doi: 10.1002/ccd.26216. Epub 2015 Sep 2.

Abstract

Background: Scoring balloons produce excellent acute results in the treatment of in-stent restenosis (ISR), fibro-calcific and bifurcation lesions but have not been shown to affect the restenosis rate. A novel paclitaxel-coated scoring balloon (SB) was developed and tested to overcome this limitation.

Methods and results: SB were coated with paclitaxel admixed with a specific excipient. Patients at four clinical sites in Germany and one in Brazil with ISR of coronary bare metal stent (BMS) were randomized 1:1 to treatment with either a drug-coated or uncoated SB. Baseline and 6-month follow-up quantitative coronary angiography was performed by an independent blinded core lab and all patients will be evaluated clinically for up to one year. The primary endpoint was angiographic in-segment late lumen loss (LLL). Secondary endpoints included the rate of clinically driven target lesion revascularization (TLR), composite of major adverse cardiovascular events (MACE), stent thrombosis and other variables. Sixty-one patients were randomized (28 uncoated and 33 drug-coated SB); mean age 65 years, males 72%, and presence of diabetes 39%. At 6-month angiography, in-segment LLL was 0.48 ± 0.51 mm in the uncoated SB group versus 0.17 ± 0.40 mm in the drug-coated SB group (P = 0.01; ITT analysis). The rate of binary restenosis was 41% in the uncoated SB group versus 7% in the drug-coated SB group (P = 0.004). The MACE rate was 32% with the uncoated SB vs. 6% in the drug-coated SB group (P = 0.016). This difference was primarily due to the reduced need for clinically driven TLR in the coated SB group (3% vs. 32% P = 0.004).

Conclusions: A novel paclitaxel-coated coronary SB has been developed and successfully used in a first-in-human randomized controlled trial [ClinicalTrials.gov Identifier: NCT01495533]. © 2015 Wiley Periodicals, Inc.

Keywords: balloon; drug coated/eluting; interventional devices/innovation; stent restenosis.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Brazil
  • Cardiac Catheters*
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Coated Materials, Biocompatible*
  • Coronary Angiography
  • Coronary Artery Disease / therapy*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / etiology
  • Coronary Restenosis / therapy*
  • Female
  • Germany
  • Humans
  • Male
  • Metals
  • Middle Aged
  • Paclitaxel / administration & dosage*
  • Paclitaxel / adverse effects
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Retreatment
  • Stents*
  • Time Factors
  • Tomography, Optical Coherence
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Metals
  • Paclitaxel

Associated data

  • ClinicalTrials.gov/NCT01495533