Aim: Two inhaler devices (Respimat® and HandiHaler®) are available for tiotropium, a long acting anticholinergic agent. We aimed to analyze drug utilization, off-label usage and generalizability of the TIOSPIR trial results for both devices.
Methods: Patients aged ≥18 years exhibiting at least one documented prescription of tiotropium in the database of the Association of Statutory Health Insurance Physicians, Bavaria, Germany, were included (years 2004-2008). Annual period prevalence rates (PPRs) were calculated stratified by age, gender and inhaler devices. Off-label usage (patients lacking a chronic obstructive pulmonary disease (COPD) diagnosis) and the proportion of patients meeting the inclusion and exclusion criteria of the TIOSPIR trial were analyzed.
Results: Between 2004 and 2008, PPRs increased and varied between 49.2 and 74.5 per 10 000 persons for HandiHaler® and between 1.5 and 9.3 per 10 000 persons for Respimat®. Small differences regarding patient characteristics existed between the two inhaler devices. Only about 30% (HandiHaler® 32.1%, Respimat® 30.0%) of the database patients receiving tiotropium could be theoretically included in the TIOSPIR trial.
Conclusions: Comparing the two tiotropium devices, no clinically relevant differences regarding patient and prescribing characteristics were revealed. Results of the TIOSPIR trial were generalizable only to a minority of our study patients, underlining the need for real-life data.
Keywords: COPD; TIOSPIR trial; real-life usage; secondary data analysis; tiotropium.
© 2015 The British Pharmacological Society.