A tetraquinoxaline cavitand functionalized with methylenoxy bridges at the upper rim is proposed as selective solid-phase microextraction (SPME) coating for the determination of BTEX at trace levels in air. The SPME fibers were characterized in terms of film thickness, morphology, thermal stability and extraction capabilities. An average coating thickness of 35 (±4) μm, a thermal stability up to 350 °C and a good fiber-to-fiber and batch-to-batch repeatability with RSD lower than 15% were obtained. Excellent enrichment factors ranging from 360-700 × 10(3) were obtained for the investigated compounds. Finally, method validation proved the capabilities of the developed coating for the selective sampling of BTEX, achieving LOD values in the 0.4-1.2 ng m(-3) range.
Keywords: Air monitoring; BTEX; Cavitands; Solid-phase microextraction.