Myocardial infarct sizing by late gadolinium-enhanced MRI: Comparison of manual, full-width at half-maximum, and n-standard deviation methods

J Magn Reson Imaging. 2016 Nov;44(5):1206-1217. doi: 10.1002/jmri.25285. Epub 2016 Apr 20.

Abstract

Purpose: To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]).

Materials and methods: 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement.

Results: Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation.

Conclusion: The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217.

Keywords: full-width at half-maximum, FWHM; late gadolinium enhancement, LGE; myocardial infarct sizing; n-standard deviation, n-SD.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Algorithms
  • Chronic Disease
  • Contrast Media / administration & dosage
  • Data Interpretation, Statistical*
  • Female
  • Gadolinium / administration & dosage*
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Longitudinal Studies
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Myocardial Infarction / diagnostic imaging*
  • Myocardial Infarction / pathology*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Severity of Illness Index*

Substances

  • Contrast Media
  • Gadolinium