Evaluation of the Removal Bacteria on Failed Titanium Implants After Irradiation With Erbium-Doped Yttrium Aluminium Garnet Laser

J Craniofac Surg. 2016 Jul;27(5):1202-4. doi: 10.1097/SCS.0000000000002735.

Abstract

Peri-implantitis may occur because of biologic or mechanical factors. It can be treated by a variety of methods. The aim of the present study is to evaluate implant surface of failed oral titanium implants after being irradiated with erbium laser.

MeSH terms

  • Bacteria / isolation & purification*
  • Humans
  • Laser Therapy / methods*
  • Lasers, Solid-State / therapeutic use*
  • Microscopy, Electron, Scanning
  • Mouth Mucosa / microbiology
  • Mouth Mucosa / ultrastructure
  • Peri-Implantitis / diagnosis
  • Peri-Implantitis / microbiology
  • Peri-Implantitis / surgery*
  • Prostheses and Implants / adverse effects
  • Prostheses and Implants / microbiology*
  • Prosthesis-Related Infections / diagnosis
  • Prosthesis-Related Infections / microbiology
  • Prosthesis-Related Infections / surgery*
  • Titanium / adverse effects*
  • Treatment Outcome

Substances

  • Titanium