Background: To evaluate the efficacy in controlling intraocular pressure (IOP) with endoscopic cyclophotocoagulation (ECP) versus implantation of a second glaucoma drainage device (GDD-2) in the treatment of uncontrolled glaucoma with a prior aqueous tube shunt.
Design: A nonrandomized retrospective chart review.
Participants: Patients with refractory glaucoma following a failed initial tube shunt (Baerveldt Glaucoma Implant 350), who underwent ECP or GDD-2 with Baerveldt Glaucoma Implant as a second surgery. Twenty-five eyes underwent ECP, and 48 eyes received a GDD-2.
Methods: ECP or second tube-shunt surgery.
Main outcome measures: Reduction in IOP and antiglaucoma medications, and Kaplan-Meier survival with success defined as lOP ≥ 5 mmHg and ≤ 21 mmHg and ≥ 20% reduction from preoperative IOP. Secondary outcome measures were visual acuity and the presence of any postoperative complications.
Results: Both ECP and GDD-2 significantly lowered IOP (Student's t test) and number of antiglaucoma medications (Wilcoxon paired signed rank test). There were no significant differences in postoperative IOP (Student's t test) or antiglaucoma medications (Mann Whitney test) between ECP and GDD-2 at 6 and 12 months. There was also no difference in the Kaplan-Meier survival outcomes between the two groups.
Conclusion: Both ECP and GDD-2 are both effective as second surgeries for refractory glaucoma that has failed a prior aqueous shunt.
Keywords: aqueous tube shunt; endoscopic cyclophotocoagulation; glaucoma drainage device; refractory glaucoma.
© 2016 Royal Australian and New Zealand College of Ophthalmologists.