The patient was admitted to the Department of Cardiac Surgery of the J. Struś City Hospital in Poznan due to infective endocarditis involving the aortic, mitral, and tricuspid valves. Implantation of three biological valve prostheses proceeded without complications. Starting on day 23, the patient's general condition deteriorated, with high fever. Despite postoperative antibiotic therapy, transesophageal echocardiography revealed the presence of vegetation on the bioprosthetic aortic valve. On the 46th day after the initial surgery, the patient required replacement of the aortic bioprosthesis, which exhibited the presence of numerous vegetations. The bioprosthetic mitral and tricuspid valves were not affected by the degenerative process. On the 12th day after the reimplantation of the bioprosthetic aortic valve, the patient was discharged from the hospital in good general condition.
Pacjent został przyjęty do oddziału kardiochirurgii Wielospecjalistycznego Szpitala Miejskiego im. J. Strusia w Poznaniu z powodu infekcyjnego zapalenia wsierdzia obejmującego zastawkę aortalną, mitralną oraz trójdzielną. Operacja polegająca na implantacji trzech biologicznych protez zastawkowych przebiegła bez powikłań. W 23. dobie stan ogólny pacjenta się pogorszył, towarzyszyła wysoka temperatura. Pomimo zastosowania pooperacyjnie antybiotykoterapii w przezprzełykowym badaniu echokardiograficznym stwierdzono obecność wegetacji na bioprotezie zastawki aortalnej. W 46. dobie po pierwotnej operacji pacjent ponownie trafił na salę operacyjną w celu wymiany bioprotezy zastawki aortalnej, na której obecne były liczne wegetacje. Bioproteza zastawki mitralnej i trójdzielnej nie były objęte procesem degeneracyjnym. W 12. dobie po ponownej implantacji bioprotezy zastawki aortalnej pacjent w stanie ogólnym dobrym został wypisany z oddziału.
Keywords: infective endocarditis; valve bioprosthesis implantation.