Retriever wire supported carotid artery revascularization (ReWiSed CARe) in acute ischemic stroke with underlying tandem occlusion caused by an internal carotid artery dissection: Technical note

Interv Neuroradiol. 2017 Jun;23(3):289-292. doi: 10.1177/1591019917690916. Epub 2017 Feb 5.

Abstract

We hereby report a novel technical approach for the treatment of acute stroke with underlying tandem occlusion. The so-called retriever wire supported carotid artery revascularization (ReWiSed CARe) technique, utilizing the wire of a stent-retriever as a guiding wire for carotid artery stenting, is technically feasible in tandem occlusions caused by an internal carotid artery (ICA) dissection or high grade ICA stenosis. This technique eliminates the need to use a long microwire in order to maintain the position inside the true lumen of a dissection. Additionally, it leads to anterograde perfusion through the released stent-retriever during the time of ICA stenting, which is favorable in all tandem occlusion cases.

Keywords: Carotid artery dissection; carotid artery stenting; stroke.

Publication types

  • Case Reports

MeSH terms

  • Brain Ischemia / diagnostic imaging
  • Brain Ischemia / etiology*
  • Brain Ischemia / surgery*
  • Carotid Artery, Internal, Dissection / complications*
  • Carotid Artery, Internal, Dissection / diagnostic imaging
  • Carotid Artery, Internal, Dissection / surgery*
  • Cerebral Angiography
  • Cerebral Revascularization / instrumentation
  • Cerebral Revascularization / methods*
  • Fatal Outcome
  • Humans
  • Male
  • Middle Aged
  • Stents*
  • Stroke / diagnostic imaging
  • Stroke / etiology*
  • Stroke / surgery*
  • Tomography, X-Ray Computed