Background: Intraprocedural aneurysm sac embolization (embo-EVAR) during endovascular abdominal aneurysm repair (EVAR) using coils and fibrin glue is a technique for preventing type II endoleak (EII). Our aim is to evaluate feasibility, safety and clinical outcome of this promising approach.
Materials and methods: A retrospective clinical case analysis of 72 patients who underwent EVAR during the period 2011-2014. Two groups were compared at 6 and 12 months follow-up with contrast media computed tomography scan and contrast-enhanced ultrasound (CEUS) imaging: consecutively, 36 patients (group A) treated with classic EVAR and 36 patients (group B) treated with embo-EVAR. Coils were released filling better as possible the aneurysm sac; the embolization was completed by injecting fibrin glue. Device and materials used, differential systemic and sac pressures, presence of any endoleak, and complication were registered.
Results: In our experience, we had 100% technical success without surgical conversion. Embo-EVAR was performed, after endograft deployment, in group B patients, all with ratio of Δ-pressures (obtained from Δ-sac pressure/Δ-differential pressure) > 0.16. No early or late complications occurred and mortality was nil. Follow-up was performed with computed tomography-angiography and CEUS at 6 and 12 months. We observed 9 type II and 1 type Ia endoleak in group A and 2 type II and 1 type Ib endoleaks in group B. Mean radiation exposure time was 30.3 min in group A and 43.3 min in group B. EVAR procedure average cost was 9,000 €. The average cost of sac embolization was 1,500€.
Conclusions: Although a randomized study is necessary, embo-EVAR may be a valid approach to prevent type II endoleaks and further complications. Mild costs and exposure-dose increase could be accepted to avoid reinterventions, and in our experience, it could be routinely performed with excellent results.
Copyright © 2017 Elsevier Inc. All rights reserved.