Peak enhancement ratio of myocardium to aorta for identification of myocardial ischemia using dynamic myocardial computed tomography perfusion imaging

J Cardiol. 2017 Dec;70(6):565-570. doi: 10.1016/j.jjcc.2017.04.002. Epub 2017 May 10.

Abstract

Background: This study aimed to evaluate the feasibility of peak enhancement (PE) ratio of myocardium to aorta (PER) derived from stress dynamic computed tomography myocardial perfusion imaging (CTP) for the detection of myocardial ischemia assessed by magnetic resonance (MR) imaging.

Methods: Forty-four patients who underwent stress dynamic CTP and MR imaging were retrospectively evaluated. From the time-attenuation curve, myocardial PE, PER, and myocardial blood flow (MBF) were calculated on a segment-based analysis. The correlation between myocardial and aortic PE was assessed by Spearman's correlation, and the differences in myocardial PE and PER between normal and ischemic myocardium were assessed by the Mann-Whitney U-test. The diagnostic accuracies of myocardial PE, PER, and MBF for detecting myocardial ischemia were compared by receiver operating characteristic analysis.

Results: Of 704 segments, 258 segments (37%) were diagnosed as myocardial ischemia with MR imaging. Myocardial and aortic PE were significantly correlated in both normal and ischemic segments (r=0.76 and 0.58; p<0.05, in each). The myocardial PE and PER of ischemic segments were significantly lower than those of normal segments (p<0.05, in each). Sensitivity and specificity were 61% [95% confidence interval (CI), 55-70%] and 83% (95% CI, 73-87%) for myocardial PE, 78% (67-88%) and 82% (95% CI, 70-91%) for PER, and 81% (95% CI, 73-87%) and 85% (95% CI, 79-92%) for MBF. There was a significantly larger area under the curve for PER (0.87; 95% CI, 0.84-0.90) and MBF (0.88; 95%CI, 0.85-0.91), compared to myocardial PE (0.75; 95% CI, 0.70-0.79) (p<0.05, in each). There was no significant difference in area under the curve between PER and MBF.

Conclusions: The semi-quantitative parameter of PER showed a high diagnostic accuracy for the detection of myocardial ischemia, comparable to that of MBF.

Keywords: Computed tomography; Coronary artery disease; Magnetic resonance imaging; Myocardial blood flow; Myocardial ischemia.

MeSH terms

  • Aged
  • Aorta / diagnostic imaging*
  • Female
  • Heart / diagnostic imaging*
  • Humans
  • Magnetic Resonance Imaging / methods
  • Male
  • Middle Aged
  • Myocardial Ischemia / diagnostic imaging*
  • Myocardial Perfusion Imaging / methods
  • Predictive Value of Tests
  • ROC Curve
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods