Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate

Medicine (Baltimore). 2017 Jun;96(24):e7200. doi: 10.1097/MD.0000000000007200.

Abstract

Despite the technological advance in 3-dimensional (3D) mapping, radiation exposure during catheter ablation of atrial fibrillation (AF) continues to be a major concern in both patients and physicians. Previous studies reported substantial radiation exposure (7369-8690 cGy cm) during AF catheter ablation with fluoroscopic settings of 7.5 frames per second (FPS) under 3D mapping system guidance. We evaluated the efficacy and safety of a low-frame-rate fluoroscopy protocol for catheter ablation for AF.Retrospective analysis of data on 133 patients who underwent AF catheter ablation with 3-D electro-anatomic mapping at our institute from January 2014 to May 2015 was performed. Since January 2014, fluoroscopy frame rate of 4-FPS was implemented at our institute, which was further decreased to 2-FPS in September 2014. We compared the radiation exposure quantified as dose area product (DAP) and effective dose (ED) between the 4-FPS (n = 57) and 2-FPS (n = 76) groups.The 4-FPS group showed higher median DAP (599.9 cGy cm; interquartile range [IR], 371.4-1337.5 cGy cm vs. 392.0 cGy cm; IR, 289.7-591.4 cGy cm; P < .01), longer median fluoroscopic time (24.4 min; IR, 17.5-34.9 min vs. 15.1 min; IR, 10.7-20.1 min; P < .01), and higher median ED (1.1 mSv; IR, 0.7-2.5 mSv vs. 0.7 mSv; IR, 0.6-1.1 mSv; P < .01) compared with the 2-FPS group. No major procedure-related complications such as cardiac tamponade were observed in either group. Over follow-up durations of 331 ± 197 days, atrial tachyarrhythmia recurred in 20 patients (35.1%) in the 4-FPS group and in 27 patients (35.5%) in the 2-FPS group (P = .96). Kaplan-Meier survival analysis revealed no significant different between the 2 groups (log rank, P = .25).In conclusion, both the 4-FPS and 2-FPS settings were feasible and emitted a relatively low level of radiation compared with that historically reported for DAP in a conventional fluoroscopy setting.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Atrial Fibrillation / diagnostic imaging*
  • Atrial Fibrillation / surgery*
  • Cardiac Imaging Techniques / methods*
  • Catheter Ablation*
  • Feasibility Studies
  • Female
  • Fluoroscopy / methods*
  • Follow-Up Studies
  • Humans
  • Imaging, Three-Dimensional / methods
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Operative Time
  • Radiation Dosage
  • Recurrence
  • Retrospective Studies
  • Surgery, Computer-Assisted / methods*