Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study

BMJ Open. 2017 Jul 10;7(7):e014655. doi: 10.1136/bmjopen-2016-014655.

Abstract

Background: Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented.

Purpose: To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain.

Methods: Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography.

Results: Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively.

Conclusions: Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value.

Trial registration number: ClinicalTrials.gov Identifier: NCT01374607.

Keywords: acute coronary syndrome; ischemia; positron emission tomography; troponin.

Publication types

  • Observational Study

MeSH terms

  • Acute Coronary Syndrome / diagnostic imaging*
  • Aged
  • Biomarkers / blood
  • Chest Pain / etiology
  • Clinical Decision-Making*
  • Coronary Angiography
  • Female
  • Humans
  • Male
  • Middle Aged
  • Positron Emission Tomography Computed Tomography
  • Predictive Value of Tests
  • Prospective Studies
  • ROC Curve
  • Switzerland
  • Troponin T / blood*

Substances

  • Biomarkers
  • Troponin T

Associated data

  • ClinicalTrials.gov/NCT01374607