Real-time intraprocedural 18F-FDG PET/CT-guided biopsy using automated robopsy arm (ARA) in the diagnostic evaluation of thoracic lesions with prior inconclusive biopsy results: initial experience from a tertiary health care centre

Br J Radiol. 2017 Dec;90(1080):20170258. doi: 10.1259/bjr.20170258. Epub 2017 Oct 27.

Abstract

Objective: The aim of this study was to assess the feasibility and appraise the diagnostic utility of real time 18F-FDG PET/CT-guided biopsy under automated robopsy arm (ARA) guidance for the evaluation of thoracic lesions with prior inconclusive biopsy results.

Methods: PET/CT-guided biopsy of thoracic lesions was performed in patients who had at least one previous inconclusive biopsy. A total of 25 patients (male:female-18 males, 7 females; age: range, 13-75; mean, 53.7) were included in this study. All these patients underwent percutaneous needle biopsies under real-time PET/CT guidance using ARA (ROBIO-EX, Perfint healthcare Pvt Ltd, Chennai, India) needle navigation technique. Histopathology and clinical follow-up results were reviewed for assessing the accuracy of procedures.

Results: Adequate representative tissue sample could be retrieved in all the patients. No major procedure-related complications were encountered in any patient. Of the 25 procedures, 21 lesions were positive for malignancy and benign findings were observed in the other 4 lesions on histopathology. None of the patients required further biopsy in arriving at a final diagnosis. Overall diagnostic yield of the procedure was 100%.

Conclusion: Real time 18F-FDG PET/CT guidance for percutaneous biopsies of lung and mediastinal lesions is a feasible technique with potential utility in patients with previous inconclusive biopsy results. Advances in knowledge: 18F-FDG PET/CT guidance reduces the sampling errors by specifically targeting areas of viability and avoiding necrosis/atelectasis. A navigational tool like ARA is thought to help in accurately targeting these areas.

Publication types

  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Biopsy, Needle / instrumentation
  • Equipment Design
  • Feasibility Studies
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Image-Guided Biopsy / instrumentation
  • Image-Guided Biopsy / methods
  • Male
  • Middle Aged
  • Positron Emission Tomography Computed Tomography / instrumentation*
  • Positron Emission Tomography Computed Tomography / methods
  • Radiopharmaceuticals
  • Robotics / instrumentation
  • Tertiary Care Centers
  • Thoracic Neoplasms / diagnostic imaging
  • Thoracic Neoplasms / pathology*
  • Young Adult

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18