Use of 18F-FDG PET-CT imaging to determine internal mammary lymph node location for radiation therapy treatment planning in breast cancer patients

Pract Radiat Oncol. 2017 Nov-Dec;7(6):373-381. doi: 10.1016/j.prro.2016.11.001. Epub 2016 Nov 5.

Abstract

Purpose: Adjuvant internal mammary lymph node (IMN) radiation is often delivered with 2-dimensional techniques that use anatomic landmarks and predetermined depths for field placement and dose specification. In contrast, 3-dimensional planning uses the internal mammary vessels (IMVs) to localize the IMNs for planning. Our purpose was to determine if localization of the involved IMN (i-IMN) by 18F-labeled fluorodeoxyglucose positron emission tomography-computed tomography (18F-FDG PET-CT) offers opportunities to improve treatment.

Methods and materials: Breast cancer patients (n = 80) who had i-IMNs (n = 112) on PET-CT for initial staging (n = 40) or recurrence (n = 40) were studied. Size, intercostal space (IC), and distance from skin, sternum, and IMVs were recorded. Effects on 2- and 3-dimensional planning were evaluated.

Results: Most i-IMNs (94.6%) were in the first to third ICs. Few were in the fourth (4.5%) or fifth (0.9%) IC. Mean i-IMN depth was 3.4 cm (range, 1.1-7.3 cm). Prescriptive depths of 4, 5, and 6 cm would result in undertreatment of 25%, 10.7%, and 5.3% of IMNs, respectively. Most IMNs (86.6%) were lateral or adjacent to the sternal edge. Only 13.4% of IMNs were posterior to the sternum. Use of the ipsilateral or contralateral sternal edge for field placement increases the risk of geographic miss or excess normal tissue exposure. Most i-IMNs were adjacent to (83%) or ≤0.5 cm (14%) from the IMV edge. Three (3%) were >0.5 cm beyond the IMV edge. The clinical target volume (CTV) defined by the first to third ICs encompassed 78% of i-IMNs. IMN-CTV coverage of i-IMNs increased with inclusion of the fourth IC (82%), 0.5 cm medial and lateral margin expansion (93%), or both (96.5%).

Conclusion: Two-dimensional treatment techniques risk geographic miss of IMNs and exposure of excess normal tissue to radiation. An IMN-CTV defined by the IMVs from the first to third ICs with 0.5-cm medial and lateral margin expansion encompasses almost all i-IMNs identified on PET-CT imaging. Inclusion of the fourth IC offers modest coverage improvement, and its inclusion should be weighed against potential increase in cardiac exposure.

Summary: The use of 2-dimensional treatment techniques for adjuvant internal mammary lymph node (IMN) radiation may cause geographic miss of tumor and expose normal tissue to radiation injury. Conformal 3-dimensional planning improves coverage and reduces risk of normal tissue damage by using the internal mammary vessel to define an IMN clinical target volume (CTV). Contouring the IMN-CTV from the first to third intercostal spaces with a 0.5-cm expansion medially and laterally encompasses most IMN. Positron emission tomography-computed tomography may have a role in radiation planning by identifying involved-IMN for dose escalation.

MeSH terms

  • Adult
  • Breast Neoplasms / diagnostic imaging*
  • Breast Neoplasms / pathology
  • Breast Neoplasms / radiotherapy*
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Lymph Nodes / pathology
  • Lymph Nodes / radiation effects
  • Lymphatic Metastasis / radiotherapy*
  • Middle Aged
  • Positron Emission Tomography Computed Tomography / methods*
  • Radiotherapy Planning, Computer-Assisted / methods

Substances

  • Fluorodeoxyglucose F18