Right versus left parasternal electrode position in the entirely subcutaneous ICD

Clin Res Cardiol. 2018 May;107(5):389-394. doi: 10.1007/s00392-017-1194-y. Epub 2017 Dec 28.

Abstract

Objectives: The subcutaneous implantable cardioverter defibrillator (S-ICD®) has been established as an alternative to conventional transvenous ICD for the prevention of sudden cardiac death. Initial studies have shown safety and efficacy of the system with a left parasternal (LP) electrode. However, several case studies reported a right parasternal (RP) position. The purpose of this study was to analyze shock efficacy and safety of an RP electrode position.

Methods: Between June 2010 and May 2016, 120 S-ICD® were implanted at our institution. On the basis of the heart location on preoperative chest radiography (CXR), the investigators decided on an RP (n = 52) or LP electrode position (n = 68). All perioperative induced VF episodes, and spontaneous appropriate and inappropriate episodes during follow-up were analyzed.

Results: Patients with an RP electrode did not differ in terms of age, sex, or ejection fraction. A statistically significant difference in underlying cardiac disease was observed between the RP and LP electrode group, with more patients with channelopathies in the RP electrode group and more patients with non-ischemic cardiomyopathy in the LP electrode group. During a mean follow-up of 24.3 ± 19.5 months, 27 appropriate (19 in the LP group and 8 in the RP group) and 28 inappropriate (18 LP and 10 RP) ICD shocks occurred (p value = NS).

Conclusions: In the present study, an RP electrode position was chosen on the basis of chest radiographic characteristics and was efficient in terms of sensing and shock efficacy. Thus, a right-sided electrode implant might be an alternative if a left-sided electrode implant is inadequate. It might also be favorable for young patients with narrow heart silhouettes in the midsagittal position.

Keywords: Electrode; Subcutaneous ICD; Sudden cardiac death.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Arrhythmias, Cardiac / diagnosis
  • Arrhythmias, Cardiac / etiology
  • Arrhythmias, Cardiac / prevention & control*
  • Clinical Decision-Making
  • Databases, Factual
  • Death, Sudden, Cardiac / etiology
  • Death, Sudden, Cardiac / prevention & control*
  • Defibrillators, Implantable*
  • Electric Countershock / adverse effects
  • Electric Countershock / instrumentation*
  • Electric Countershock / methods
  • Female
  • Germany
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Patient Selection
  • Predictive Value of Tests
  • Prosthesis Design
  • Retrospective Studies
  • Risk Factors
  • Treatment Outcome