Hospital Outcome and Risk Indices of Mortality after redo-mitral valve surgery in Potential Candidates for Transcatheter Procedures: Results From a European Registry

J Cardiothorac Vasc Anesth. 2018 Apr;32(2):646-653. doi: 10.1053/j.jvca.2017.09.039. Epub 2017 Sep 28.

Abstract

Objective: Transcatheter mitral valve-in-valve/valve-in-ring procedures (TM-VIVoR) are increasing. The authors aimed to identify independent predictors for hospital mortality in redo mitral valve surgery as possible future selection criteria for TM-VIVoR.

Design: Retrospective multicenter registry.

Setting: Tertiary university and community hospitals.

Participants: Two-hundred and sixty patients (out of 920 enrolled) who are potentially candidates for TM-VIVoR undergoing redo-surgery.

Interventions: Redo mitral surgery.

Measurements and main results: Regression analyzes and receiver operating characteristic (ROC) curves identified independent predictors of death. Patients potentially candidates for TM-VIVoR reported significant hospital mortality (9.2%; EuroSCORE II: 13.2 ± 13.1, Society of Thoracic Surgeons [STS] score: 6.2 ± 3.1) and major morbidity (3.8% acute myocardial infarction, 5% stroke, 16.9% perioperative respiratory failure, 16.5% acute renal insufficiency, 25% massive transfusions). EuroSCORE II (odds ration [OR] 1.06; confidence interval [CI] 1.01-1.10; p = 0.005), STS score (OR 1.58; CI 1.27-1.97; p = 0.001), age at surgery (OR 1.05; CI 1.00-1.15; p = 0.05), preoperative dialysis (OR 2.5; CI 1.8-12.6; p = 0.042), left ventricular ejection fraction (LVEF) <30% (OR 4.8; CI 1.12-37.1; p = 0.021), severe pulmonary hypertension (OR 7.5; CI 1.9-29.4; p = 0.003), and previous coronary artery bypass grafting (CABG) (OR 11.8; CI 1.7-36.9; p = 0.002) were independent predictors of hospital mortality. ROC analyses reported good prediction for EuroSCORE II (AUC: 0.76; cut-off value: >13.1; 70.8% sensitivity and 68.2% specificity) and better prediction for STS score (AUC: 0.81; cut-off value: 7.4; 75.0% sensitivity and 66.2% specificity). Quintiles stratification identified EuroSCORE II ≥18.7 (5th quintile, observed mortality: 19.3%) and STS score >9.1 as strong predictors of death within each risk-categorization (OR 5.9 and 12.1, respectively).

Conclusions: High EuroSCORE II and STS scores, advanced age at surgery, LVEF <30%, previous CABG, severe pulmonary hypertension or preoperative dialysis might represent in the future preferred indications for TM-VIVoR in the redo-mitral surgery scenario.

Keywords: failed bioprosthesis; mitral; redo; trans-catheter valve; valve-in-ring; valve-in-valve.

Publication types

  • Multicenter Study

MeSH terms

  • Age Factors
  • Aged
  • Aged, 80 and over
  • Europe
  • Female
  • Heart Valve Prosthesis Implantation / mortality*
  • Heart Valve Prosthesis Implantation / trends
  • Hospital Mortality* / trends
  • Humans
  • Male
  • Middle Aged
  • Mitral Valve Insufficiency / mortality*
  • Mitral Valve Insufficiency / surgery*
  • Prospective Studies
  • Registries*
  • Reoperation / mortality*
  • Reoperation / trends
  • Retrospective Studies
  • Risk Factors
  • Treatment Outcome