Prefrontal hemodynamic changes measured using near-infrared spectroscopy during the Valsalva maneuver in patients with orthostatic intolerance

Neurophotonics. 2018 Jan;5(1):015002. doi: 10.1117/1.NPh.5.1.015002. Epub 2018 Jan 26.

Abstract

The Valsalva maneuver (VM) with beat-to-beat blood pressure and heart rate monitoring are used to evaluate orthostatic intolerance (OI). However, they lack the ability to detect cerebral hemodynamic changes, which may be a cause of OI symptoms. Therefore, we utilized near-infrared spectroscopy during VM. Patients with OI symptoms and normal healthy subjects were recruited. Patients were subgrouped according to VM results: patients with normal VM (NVM) and abnormal VM (AbVM). Oxyhemoglobin (HbO), deoxyhemoglobin, and total hemoglobin changes were measured at four different source-detector distances (SD) (15, 30, 36, and 45 mm), and latency, amplitude, duration, and integrated total signal were calculated. Those parameters were compared between a normal healthy control (HC) group and the two OI patient subgroups. We found that HbO increment latency at 30-mm SD in the HC, NVM, and AbVM groups was as follows: [Formula: see text], [Formula: see text], and [Formula: see text], respectively ([Formula: see text]). Among the four parameters we evaluated, latency of HbO increment was the best marker for differentiating OI.

Keywords: Valsalva maneuver; near-infrared; orthostatic intolerance; spectroscopy.