Is there a difference in bleeding after left ventricular assist device implant: centrifugal versus axial?

J Cardiothorac Surg. 2018 Feb 13;13(1):22. doi: 10.1186/s13019-018-0703-z.

Abstract

Background: Continuous-flow left ventricular assist devices (CF-LVAD) have become the standard of care for patients with end stage heart failure. Device reliability has increased, bringing the potential for VAD, compared to transplant, into debate. However, complications continue to limit VADs as first line therapy. Bleeding is a major morbidity. A debate exists as to the difference in bleeding profile between the major centrifugal and axial flow devices. We hypothesized that there would be similar adverse bleeding event profiles between the 2 major CF-LVADs.

Methods: We retrospectively investigated isolated CF LVADs performed at our institution between July 2010 and July 2015: HeartMateII (HMII, n = 105) and HeartWare (HVAD, n = 34). We reviewed demographic, perioperative and short- and long-term outcomes.

Results: There was no significant difference in demographics or comorbidities. There was a low incidence of gastrointestinal (GI) bleed 3.9% in HMII and 2.9% in HVAD (p = 0.78). Preoperatively, the cohorts did not differ in coagulation measures (p = 0.95). Within the post-operative period, there was no difference in product transfusion: red blood cells (p = 0.10), fresh frozen plasma (p = 0.19), and platelets (p = 0.89). Post-operatively, a higher but not significantly different number of HMII patients returned to the operating room for bleeding (n = 27) compared to HVAD (n = 6, p = 0.35). There was no difference in rates of stroke (p = 0.65), re-intubation (p = 0.60), driveline infection (p = 0.05), and GI bleeding (p = 0.31). The patients had equivalent ICU LOS (p = 0.86) and index hospitalization LOS (p = 0.59).

Conclusion: We found no difference in the rate of bleeding complications between the current commercially available axial and centrifugal flow devices.

Keywords: Gastrointestinal bleeding; Left ventricular assist device.

MeSH terms

  • Female
  • Gastrointestinal Hemorrhage / etiology*
  • Heart Failure / surgery*
  • Heart-Assist Devices / adverse effects*
  • Humans
  • Length of Stay
  • Male
  • Middle Aged
  • Postoperative Complications*
  • Reproducibility of Results
  • Retrospective Studies
  • Stroke / etiology
  • Surgical Wound Infection / etiology