Impact of controlled attenuation parameter on detecting fibrosis using liver stiffness measurement

Aliment Pharmacol Ther. 2018 Apr;47(7):989-1000. doi: 10.1111/apt.14529. Epub 2018 Feb 15.

Abstract

Background: Liver fibrosis is often accompanied by steatosis, particularly in patients with non-alcoholic fatty liver disease (NAFLD), and its non-invasive characterisation is of utmost importance. Vibration-controlled transient elastography is the non-invasive method of choice; however, recent research suggests that steatosis may influence its diagnostic performance. Controlled Attenuation Parameter (CAP) added to transient elastography enables simultaneous assessment of steatosis and fibrosis.

Aim: To determine how to use CAP in interpreting liver stiffness measurements.

Methods: This is a secondary analysis of data from an individual patient data meta-analysis on CAP. The main exclusion criteria for the current analysis were unknown aetiology, unreliable elastography measurement and data already used for the same research question. Aetiology-specific liver stiffness measurement cut-offs were determined and used to estimate positive and negative predictive values (PPV/NPV) with logistic regression as functions of CAP.

Results: Two thousand and fifty eight patients fulfilled the inclusion criteria (37% women, 18% NAFLD/NASH, 42% HBV, 40% HCV, 51% significant fibrosis ≥ F2). Youden optimised cut-offs were only sufficient for ruling out cirrhosis (NPV of 98%). With sensitivity and specificity-optimised cut-offs, NPV for ruling out significant fibrosis was moderate (70%) and could be improved slightly through consideration of CAP. PPV for significant fibrosis and cirrhosis were 68% and 55% respectively, despite specificity-optimised cut-offs for cirrhosis.

Conclusions: Liver stiffness measurement values below aetiology-specific cut-offs are very useful for ruling out cirrhosis, and to a lesser extent for ruling out significant fibrosis. In the case of the latter, Controlled Attenuation Parameter can improve interpretation slightly. Even if cut-offs are very high, liver stiffness measurements are not very reliable for ruling in fibrosis or cirrhosis.

Publication types

  • Meta-Analysis
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Biopsy
  • Elasticity
  • Elasticity Imaging Techniques / methods*
  • Female
  • Humans
  • Liver / diagnostic imaging*
  • Liver / pathology
  • Liver Cirrhosis / diagnosis*
  • Liver Cirrhosis / pathology
  • Liver Cirrhosis / physiopathology
  • Liver Function Tests / methods
  • Liver Function Tests / standards
  • Male
  • Middle Aged
  • Non-alcoholic Fatty Liver Disease / diagnosis
  • Non-alcoholic Fatty Liver Disease / pathology
  • Retrospective Studies
  • Sensitivity and Specificity