Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials

BMJ Open. 2018 Feb 22;8(2):e017231. doi: 10.1136/bmjopen-2017-017231.

Abstract

Objective: The study sought to compare angiographic and clinical outcomes of new-generation drug-eluting stents (DES) versus drug-coated balloon (DCB) in patients with coronary in-stent restenosis (ISR).

Design: Meta-analysis using data from randomised trial found by searches on PubMed, the Cochrane Library, ClinicalTrials.gov and websites of major cardiovascular congresses.

Setting: Only randomised trials comparing DES with DCB were included.

Participants: Patients with ISR in the included trials.

Interventions: New-generation DES versus DCB.

Outcomes: The angiographic and clinical outcomes including cardiac death, all-cause death, myocardial infarction, target lesion revascularisation (TLR), target vessel revascularisation (TVR), major adverse cardiac events (MACE) and stent thrombosis were investigated.

Results: Five trials including 913 patients were eligible and included. Pooled analysis in angiographic results identified that new-generation DES were associated with higher acute luminal gain (-0.31 mm, 95% CI -0.42 to -0.20, P<0.001) and lower per cent diameter stenosis (risk ratio (RR): 0.28, 95% CI 0.02 to 0.55, P=0.04). DES significantly reduced the risk of TLR (RR: 1.96, 95% CI 1.17 to 3.28, P=0.01) compared with DCB; however, there was no statistical differences for MACE (RR: 1.21, 95% CI 0.67 to 2.17, P=0.53), myocardial infarction (RR: 1.16, 95% CI 0.55 to 2.48, P=0.69) and cardiac death (RR: 1.80, 95% CI 0.60 to 5.39, P=0.29).

Conclusions: Interventions with new-generation DES appear to be associated with significant reduction in per cent diameter stenosis and TLR at short-term follow-up, but had similar MACE, myocardial infarction and cardiac death for patients with coronary ISR compared with DCB. Appropriately powered studies with longer term follow-up are warranted to confirm these findings.

Keywords: drug-coated balloon; drug-eluting stents; in-stent restenosis; meta-analysis.

Publication types

  • Comparative Study
  • Meta-Analysis
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angioplasty, Balloon, Coronary / adverse effects
  • Cause of Death
  • Coronary Angiography
  • Coronary Restenosis / therapy*
  • Death, Sudden, Cardiac / epidemiology*
  • Death, Sudden, Cardiac / etiology
  • Drug-Eluting Stents / adverse effects*
  • Humans
  • Linear Models
  • Myocardial Infarction / epidemiology*
  • Myocardial Infarction / etiology
  • Odds Ratio
  • Prosthesis Design / instrumentation*
  • Randomized Controlled Trials as Topic
  • Treatment Outcome