Three-year follow-up of hybrid ablation for atrial fibrillation

Eur J Cardiothorac Surg. 2018 Apr 1;53(suppl_1):i26-i32. doi: 10.1093/ejcts/ezy117.

Abstract

Objectives: The single-step hybrid atrial fibrillation (AF) ablation procedure combines a transvenous endocardial and thoracoscopic epicardial approach in 1 procedure. Short-term results are encouraging, but long-term outcome data are not available.

Methods: Hybrid AF ablation was successfully performed in 64 consecutive patients (53% with persistent AF). The mean follow-up period was 1732 ± 353 days. Perprocedural endocardial touch-up of incomplete epicardial lesions was performed in 17 (26%) patients.

Results: In paroxysmal AF patients, arrhythmia-free cumulative survival rates after 1 hybrid AF ablation without Class I or III antiarrhythmic drugs procedure and without redo catheter ablation were 83%, 80% and 80% after 1, 2 and 3 years, respectively. In (long-standing) persistent AF patients, these were 82%, 79% and 79% after 1, 2 and 3 years. Thirteen (20%) patients had at least 1 recurrent episode of supraventricular arrhythmia lasting longer than 30 s: the most frequent recurrent arrhythmias were left atrial flutter and AF. No mortality or conversion to cardiopulmonary bypass, no phrenic nerve palsy and no pacemaker implantation were reported.

Conclusions: Hybrid AF ablation, combining a transvenous endocardial and thoracoscopic epicardial approach in a single procedure, results in a cumulative 3-year freedom from arrhythmia without Class I or III antiarrhythmic drugs and without redo catheter ablation of 80% in paroxysmal AF (24 of 30 patients) and 79% in non-paroxysmal AF (26 of 33 patients).

MeSH terms

  • Adult
  • Aged
  • Atrial Appendage / surgery
  • Atrial Fibrillation / surgery*
  • Cardiac Catheterization* / methods
  • Catheter Ablation* / methods
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Pericardium / surgery
  • Thoracoscopy* / methods
  • Treatment Outcome