Background: Combat casualties undergoing aeromedical evacuation are at increased risk for pressure injuries. The risk factors pressure and shear are potentially modifiable via solutions appropriate for en route care.
Objectives: To compare transcutaneous oxygen levels and skin temperatures in healthy participants under offloaded (side lying) and loaded (supine or supine with 30° backrest elevation) under 4 conditions: control (no intervention), Mepilex sacral and heel dressings, LiquiCell pad, and Mepilex plus LiquiCell.
Methods: Participants were randomly assigned to 4 groups according to ideal body weight. Backrest positions were randomized. Transcutaneous oxygen level and temperature were measured on the sacrum and the heel; skin interface pressure was measured with an XSensor pressure imaging system. Measurements were obtained for 5 minutes at baseline (offloaded), 40 minutes with participants supine, and 15 minutes offloaded.
Results: In the 40 healthy participants, interface pressure, transcutaneous oxygen level, and skin temperature did not differ between the 4 groups. Peak interface pressures were approximately 43 mm Hg for the sacrum and 50 mm Hg for the heel. Sacral transcutaneous oxygen level differed significantly between unloaded (mean, 79 mm Hg; SD, 16.5) and loaded (mean, 57 mm Hg; SD, 25.2) conditions (P < .001) in a flat position (mean, 85.2 mm Hg; SD, 13.6) and with 30° backrest elevation (mean, 66.7 mm Hg; SD, 24.2) conditions (P < .001). Results for the heels and the sacrum were similar. Sacral skin temperature increased significantly across time (approximately 1.0°C).
Conclusions: The intervention strategies did not differ in prevention of pressure injuries.
©2018 American Association of Critical-Care Nurses.