The Effect of 3.2% and 3.8% Sodium Citrate on Specialized Coagulation Tests

Arch Pathol Lab Med. 2018 Aug;142(8):992-997. doi: 10.5858/arpa.2017-0200-OA. Epub 2018 Apr 6.

Abstract

Context: - Coagulation testing is challenging and depends on preanalytic factors, including the citrate buffer concentration used.

Objective: - To better estimate preanalytic effects of the citrate buffer concentration in use, the difference between results obtained by samples with 3.2% and 3.8% citrate was evaluated.

Design: - In a prospective observational study with 76 volunteers, differences related to the citrate concentration were evaluated. For both buffer concentrations, reference range intervals were established according to the recommendations of the C28-A3 guideline published by the Clinical and Laboratory Standards Institute.

Results: - In our reagent-analyzer settings, most parameters evaluated presented good comparability between citrated samples taken with 3.2% and 3.8% trisodium buffer. The ellagic acid containing activated partial thromboplastin time reagent (aPTT-FS) indicated a systemic and proportional difference between both buffer concentrations, leading to an alteration in its reference ranges. Further, a confirmation test for lupus anticoagulant assessment (Staclot LA) showed only a moderate correlation ( rρ = 0.511) with a proportional deviation between both citrate concentrations. Further, a statistically significant difference was found in the diluted Russell viper venom time confirmation testing, coagulation factors V and VIII, and the protein C activity, which was found to be of minor clinical relevance.

Conclusions: - With caution regarding the potential impact of the reagent-analyzer combination, our findings demonstrate the comparability of data assessed with 3.2% and 3.8% buffered citrated plasma. As an exception, the aPTT-FS and the Staclot LA assay were considerably affected by the citrate concentration used. Further studies are required to confirm our finding using different reagent-analyzer combinations.

Publication types

  • Observational Study

MeSH terms

  • Blood Coagulation Tests / methods*
  • Buffers
  • Healthy Volunteers
  • Humans
  • Prospective Studies
  • Reference Values
  • Sodium Citrate*

Substances

  • Buffers
  • Sodium Citrate