Technetium-99m MAG3, a comparison with iodine-123 and iodine-131 orthoiodohippurate, in patients with renal disorders

J Nucl Med. 1988 Feb;29(2):147-58.

Abstract

A Phase I study in 12 patients with renal disorders compared the simultaneous clearances of 99mTc-labeled mercaptoacetyltriglycine (MAG3) and 131I-labeled orthoiodohippurate (OIH). The ratio of MAG3 to OIH clearance was 0.61 +/- 0.08 as a result of its smaller volume of distribution, ratio 0.65 +/- 0.09, for the clearance half-lives were similar, ratio 1.09 +/- 0.12. A Phase II study performed serially in 20 patients with equal doses of [99mTc]MAG3 and [123I]OIH gave images of equal quality. The relative renal functions were highly correlated (r = 0.97, p less than 0.001) and transit time analyses gave good correlations: parenchymal transit time index r = 0.81, p less than 0.05. We conclude that [99mTc]MAG3 has some advantages over [99mTc]DTPA and is a suitable replacement for [123I]hippuran in routine renal imaging, relative function, and transit time studies, but not for the accurate estimation of the renal plasma flow.

Publication types

  • Case Reports
  • Comparative Study
  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Adult
  • Aged
  • Female
  • Humans
  • Iodohippuric Acid* / pharmacokinetics
  • Kidney Diseases / diagnostic imaging*
  • Kidney Diseases / metabolism
  • Male
  • Middle Aged
  • Oligopeptides* / pharmacokinetics
  • Organometallic Compounds* / pharmacokinetics
  • Radioisotope Renography*
  • Technetium Tc 99m Mertiatide
  • Technetium* / pharmacokinetics

Substances

  • Oligopeptides
  • Organometallic Compounds
  • Iodohippuric Acid
  • Technetium Tc 99m Mertiatide
  • Technetium