The relationship between baseline and follow-up left ventricular ejection fraction with adverse events among primary prevention ICD patients

Am Heart J. 2018 Jul:201:17-24. doi: 10.1016/j.ahj.2018.03.017. Epub 2018 Apr 4.

Abstract

Background: Left ventricular ejection fraction (LVEF) is used to select patients for primary prevention implantable cardioverter defibrillators (ICDs). The relationship between baseline and long-term follow-up LVEF and clinical outcomes among primary prevention ICD patients remains unclear.

Methods: We studied 195 patients with a baseline LVEF ≤35% ≤6 months prior to ICD implantation and follow-up LVEF 1-3 years after ICD implantation without intervening left ventricular assist device (LVAD) or transplant. The co-primary study endpoints were: (1) a composite of time to death, LVAD, or transplant and (2) appropriate ICD therapy. We examined multivariable Cox proportional hazard models with a 3-year post-implant landmark view; the LVEF closest to the 3-year mark was considered the follow-up LVEF for analyses. Follow-up LVEF was examined using 2 definitions: (1) ≥10% improvement compared to baseline or (2) actual value of ≥40%.

Results: Fifty patients (26%) had a LVEF improvement of ≥10% and 44 (23%) had a follow-up LVEF ≥40%. Neither baseline nor follow-up LVEF was significantly associated with the composite endpoint. In contrast, both baseline and follow-up LVEF were associated with risk for long-term ICD therapies, whether follow-up LVEF was modeled as a ≥10% absolute improvement (baseline LVEF HR 0.87, CI 0.91-0.93, P < .001; follow-up LVEF HR 0.18, CI 0.06-0.53, P = .002) or a ≥40% follow-up value (baseline LVEF HR 0.89, CI 0.83-0.96, P = .001, follow-up LVEF HR 0.26, CI 0.08-0.87, P = .03).

Conclusions: Among primary prevention ICD recipients, both baseline and follow-up LVEF were independently associated with long-term risk for appropriate ICD therapy, but they were not associated with time to the composite of LVAD, transplant, or death.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Death, Sudden, Cardiac / prevention & control*
  • Defibrillators, Implantable / adverse effects*
  • Echocardiography
  • Female
  • Heart Failure / diagnosis
  • Heart Failure / physiopathology
  • Heart Failure / therapy*
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / physiopathology*
  • Humans
  • Magnetic Resonance Imaging, Cine
  • Male
  • Middle Aged
  • Primary Prevention / methods*
  • Retrospective Studies
  • Risk Factors
  • Stroke Volume / physiology*
  • Ventricular Function, Left / physiology*